14.TROUBLESHOOTING
67
Fault
code
Fault description
Possible reasons for abnormality
How to deal with
16
Low DC voltage 200V
1.
Voltage input
is
too low;
2.
Drive board fault.
1. Check the power supply;
2. Change the driver board;
18
Driver board read EE
data error
1. EEPROM has no data or data error;
2. EEPROM circuit fault.
1. Change EEPROM component;
2. Change the driver board.
19
PFC chip receive data
fault
Abnormal communication loop
.
Change the drive board.
20
PFC soft start
is abnormal
Abnormal PFC drive loop
.
Change the drive board.
21
The compressor drive
chip could not receive
data from PFC chip.
Communication loop fault.
Change the drive board.