![Hirschmann RSPE30 User Manual Download Page 32](http://html1.mh-extra.com/html/hirschmann/rspe30/rspe30_user-manual_2138135032.webp)
32
Installation RSPE30/32/35/37
Release 16 04/2019
In accordance with IEEE 802.3af and IEEE 802.3at:
Endpoint PSE
Alternative A.
1.6
Display elements
After the supply voltage is set up, the Software starts and initializes the
device. Afterwards, the device performs a self-test. During this process,
various LEDs light up.
1.6.1
Device state
These LEDs provide information about conditions which affect the operation
of the whole device.
LED
Display
Color Activity
Meaning
Power Supply voltage
—
none
Supply voltage is too low
yellow lights up
Device variants with redundant power
supply:
Supply voltage 1
or
2 is on
flashes 4 times
a period
Software update is running. Maintain the
power supply.
green lights up
Device variants with redundant power
supply:
Supply voltage 1
and
2 is on
Device variants with single power supply:
Supply voltage is on
ACA
Storage medium
ACA21
ACA31
—
none
ACA storage medium not connected
green lights up
ACA storage medium connected
flashes 3 times
a period
Device writes to/reads from the storage
medium
yellow lights up
ACA storage medium inoperative
RM
Ring Manager
—
none
No redundancy configured
green lights up
Redundancy exists
flashes 1 time
a period
Device is reporting an incorrect
configuration of the RM function
yellow lights up
No redundancy exists
Status
RM
ACA
Power