![Hirschmann PowerLION-24TP Installation Manual Download Page 55](http://html1.mh-extra.com/html/hirschmann/powerlion-24tp/powerlion-24tp_installation-manual_2138114055.webp)
A-1
Appendix A: Troubleshooting
Diagnosing Switch Indicators
Diagnosing Power Problems with the LEDs
The Power and RPU LEDs work in combination to indicate power status as follows.
Table A-1 Troubleshooting Chart
Symptom
Action
Power LED is Off
• Check connections between the switch, the power cord, and the wall
outlet.
• Contact your dealer for assistance.
Power LED is Amber
• Internal power supply has failed. Contact your local dealer for
assistance.
Diag LED is Amber
• Power cycle the switch to try and clear the condition.
• If the condition does not clear, contact your local dealer for assistance.
Stack Master LED is Flashing
Amber
• The stack has not completed its initial configuration. Wait a few
minutes for the process to complete.
• If flashing continues, check that the Master Select button is pressed in
on only one switch.
• Check that all stacking cables are properly connected.
Stack Link LED is Flashing
Green/Amber
• The uplink/downlink has failed.
• For the indicated stack link, check that the stacking cables are properly
connected. Replace the stacking cable if necessary.
• Power cycle the switch to try and clear the condition.
Link LED is Off
• Verify that the switch and attached device are powered on.
• Be sure the cable is plugged into both the switch and corresponding
device.
• Verify that the proper cable type is used and its length does not exceed
specified limits.
• Check the adapter on the attached device and cable connections for
possible defects. Replace the defective adapter or cable if necessary.
Table A-2 Power/RPU LEDs
Power LED
RPU LED
Status
Green
Green
Internal power functioning normally; RPU is present.
Green
Amber
Internal power functioning normally; RPU plugged in but faulty.
Green
Off
Internal power functioning normally; RPU not plugged in.
Amber
Green
Internal power faulty; RPU delivering power.
Off
Off
Both internal power and RPU unplugged or not functioning.
Summary of Contents for PowerLION-24TP
Page 4: ......
Page 12: ...viii...
Page 16: ...xii Contents Glossary Index...
Page 18: ...xiv Tables...
Page 20: ...xvi Figures...
Page 36: ...2 8 Network Planning 2...
Page 46: ...3 10 Installing the Switch 3...
Page 58: ...A 4 Troubleshooting A...
Page 66: ...C 4 Specifications C Standards IEEE 802 3ae 10 Gigabit Ethernet...
Page 76: ...Index Index 4...
Page 77: ......
Page 78: ......