![Hirschmann PowerLION-24TP Installation Manual Download Page 25](http://html1.mh-extra.com/html/hirschmann/powerlion-24tp/powerlion-24tp_installation-manual_2138114025.webp)
Description of Hardware
1-5
1
Figure 1-4 System LEDs
Table 1-2 System Status LEDs
LED
Condition
Status
Power
Green
Internal Power is operating normally.
Amber
Internal Power supply fault.
Off
Power off or failure.
Diag
Flashing Green
System self-diagnostic test in progress.
Green
System self-diagnostic test successfully completed.
Amber
System self-diagnostic test has detected a fault.
RPU
Green
Redundant power unit is receiving power.
Amber
Fault in redundant power unit.
Off
Redundant power unit is off.
Stack Master
Green
Switch is operating as the Master unit in the stack.
Amber
Switch is operating as a Slave unit in the stack.
Flashing Amber
System in arbitration/election state.
Off
System in standalone mode.
Stack Link
Green
Uplink and downlink operating normally.
Flashing Green
Uplink has failed.
Flashing Amber
Downlink has failed.
Off
No stacking link present.
Module
Green
An expansion module is installed in the slot.
Flashing green
An installed expansion module has been disabled.
Off
There is no module installed.
Stack ID
1-8
Indicates the switch stack ID.
The Master unit is numbered 1.
Slave units are numbered 2-8.
Off
In standalone mode.
Master
Select
St ack ID
Powe r
RPU
Diag
Module
St ac k Maste r
St ack Link
45
46
47
48
Consol e
System St atus LED s
Summary of Contents for PowerLION-24TP
Page 4: ......
Page 12: ...viii...
Page 16: ...xii Contents Glossary Index...
Page 18: ...xiv Tables...
Page 20: ...xvi Figures...
Page 36: ...2 8 Network Planning 2...
Page 46: ...3 10 Installing the Switch 3...
Page 58: ...A 4 Troubleshooting A...
Page 66: ...C 4 Specifications C Standards IEEE 802 3ae 10 Gigabit Ethernet...
Page 76: ...Index Index 4...
Page 77: ......
Page 78: ......