37
Voltage surges - DC supply connection
EN 61000-4-5
line/ground
±2 kV
±2 kV
EN 61000-4-5
line/line
±1 kV
±1 kV
Voltage surges - AC supply connection
EN 61000-4-5
line/ground
±2 kV
±2 kV
EN 61000-4-5
line/line
±1 kV
±1 kV
Voltage surges - data line
EN 61000-4-5
line/ground
±1 kV
±2 kV
Conducted disturbances
EN 61000-4-6
150 kHz ... 80 MHz
10 V
10 V
Damped oscillation - AC/DC supply connection
EN 61000-4-12
line/ground
—
—
EN 61000-4-12
line/line
—
—
Damped oscillation – data line
EN 61000-4-12
line/ground
—
—
—
EN 61000-4-12
line/line
—
—
—
Pulse magnetic field
EN 61000-4-9
—
—
—
a. EN 61131-2, CE, FCC – applies to all devices
b. According to EN 50121-4.
c. According to EN 50155.
EMC interference
immunity
Standard applications
a
Railway applications
(trackside)
b
Railway applications
(on vehicles)
c
Table 13: EMC interference immunity