![Hirschmann OCTOPUS OS3 User Manual Download Page 36](http://html1.mh-extra.com/html/hirschmann/octopus-os3/octopus-os3_user-manual_2138041036.webp)
36
Installation
OCTOPUS O
S
3
Re
lease
01
02/2
019
EMC interference
emission
Standard applications
a
a. EN 61131-2, CE, FCC – applies to all devices
Railway applications
(trackside)
b
b. According to EN 50121-4.
Railway applications
(on vehicles)
c
c. According to EN 50155.
Radiated emission
EN 55032
Class A
Class A
Class A
FCC 47 CFR Part 15
Class A
Class A
Class A
EN 61000-6-4
Fulfilled
Fulfilled
Fulfilled
Conducted emission
EN 55032
AC and DC supply connections
Class A
Class A
Class A
FCC 47 CFR Part 15
AC and DC supply connections
Class A
Class A
Class A
EN 61000-6-4
AC and DC supply connections
Fulfilled
Fulfilled
Fulfilled
EN 55032
Telecommunication connections
Class A
Class A
Class A
EN 61000-6-4
Telecommunication connections
Fulfilled
Fulfilled
Fulfilled
Table 12: EMC interference emission
EMC interference
immunity
Standard applications
a
Railway applications
(trackside)
b
Railway applications
(on vehicles)
c
Electrostatic discharge
EN 61000-4-2
Contact discharge
±4 kV
±6 kV
±6 kV
EN 61000-4-2
Air discharge
±8 kV
±8 kV
±8 kV
Electromagnetic field
EN 61000-4-3
80 MHz ... 3000 MHz
max. 10 V/m
max. 10 V/m
max. 10 V/m
EN 61000-4-3
80 MHz ... 2700 MHz
—
Fast transients (burst)
EN 61000-4-4
AC/DC supply connection
±2 kV
±4 kV
EN 61000-4-4
Data line
±4 kV
±4 kV
Table 13: EMC interference immunity