![Hirschmann OCTOPUS OS3 User Manual Download Page 23](http://html1.mh-extra.com/html/hirschmann/octopus-os3/octopus-os3_user-manual_2138041023.webp)
Installation OCTOPUS OS3
Release 01 02/2019
23
2.2
Installing and grounding the device
When you are selecting the installation location, make sure you observe
the climatic threshold values specified in the technical data.
Prevent heat from the surroundings from affecting the device.
Verify that there is at least 4 in (10 cm) of space above and below the
device.
Remove the provided transport protection caps and the transport
protection screws from the device.
2.2.1
Mounting on a flat surface
Proceed as follows:
You will find the drilling dimensions for mounting the device in the chapter
“Dimension drawings” on page 34
.
Install the device with screws on the flat surface.
Completely screw the device to the flat surface using screws through
each mounting hole. Exclusively use screws suitable for the installation
and application case to ensure flawless operation of the device.
CAUTION
BURNING HAZARD
The surfaces of the device casing may become hot. Avoid touching the
device while it is operating.
If ambient temperatures are
≥
113 °F (
≥
45 °C), exclusively install the device
in “restricted access locations” according to EN 62368.
Failure to follow these instructions can result in injury or equipment
damage.