Technical data
7.1
General data
7.2
Supply voltage
OCTOPUS OS3
Dimensions
W × H × D
See “Dimension drawings” on page 34.
Weight
17.42 lb (7.9 kg)
Mounting
See “Mounting on a flat surface” on page 23.
Pollution degree
2
Degree of protection
IP54
Table 5:
General data: OCTOPUS OS3
Supply voltage with the characteristic value N9
Rated voltage
72 V DC ... 110 V DC
Voltage range incl. maximum tolerances 50.4 V DC ... 138 V DC
Connection type
5-pin, “K”-coded M12 plug
Tightening torque
4.5 lb-in (0.51 Nm)
min. conductor diameter
AWG18 (0.75 mm²)
max. conductor diameter
AWG16 (1.5 mm²)
Power loss buffer
> 10 ms
Overload current protection on the device Non-replaceable fuse
Back-up fuse for each voltage input
Nominal rating:
max. 20 A
Characteristic:
slow blow
Peak inrush current
1 A
Connection for protective grounding
See “Grounding the device” on page 24.
Current integral I²t
0.7 A²s