5. Technical data

General data

Operating voltage

Rated voltage range DC

12 V DC to 24 V DC Safety extra-low voltage (SELV)
Relevant for North America: NEC Class 2 power source max. 5 A

Max. voltage range DC

min. 9.0 V DC to max. 32 V DC
(Not applicable under UL regulations)

Buffer time

min. 10 ms at 20.4 V DC

Potential difference between input

Potential difference to input voltage, +24 V DC: 32 V DC

voltage and housing

Potential difference to input voltage, ground: -32 V DC

Current consumption at 24 V DC

2.4 W maximum;  8.2 Btu (IT)/h

Dimensions W x H x D

60 mm x 126 mm x 31 mm

Weight

210 g

Ambient temperature

Surrounding air - 40 ºC to + 85 ºC

Note: 

Following UL508 requirements the ambient temperature is restricted to 60 °C.

Storage temperature

Surrounding air - 40 ºC to + 85 ºC

Atmospheric pressure

up to 2000 m (795 hPa, higher altitudes on demand)

Protection type

IP 67, according to EN 60529

Protection against shock and foreign particles Full shock protection, impenetrable to dust

Water protection

Protected against water penetration, during submersion under
specified pressure and time conditions

Interference proof

Discharge of static electricity

Contact discharge

EN 61000-4-2 Test level 2

Air discharge

EN 61000-4-2 Test level 3

Electromagnetic fields

EN 61000-4-3 Test level 3

Fast transients

EN 61000-4-4 Test level 3

Surge voltage symmetrical

EN 61000-4-5 Test level 2

Surge voltage asymmetrical

EN 61000-4-5 Test level 3

Cable-based RF faults

EN 61000-4-6 Test level 3

EMC emitted immunity

EN 55022

Class A

FCC 47 CFR Part 15

Class A

Stability

Vibration

IEC 60068-2-6 Test FC, testing level in line with EN 61131-2:2007

Shock

IEC 60068-2-27 Test Ea, testing level in line with EN 61131-2:2007

Certifications

cUL 508 / CSA 22.2 No.14-M91

E175531

Network size

TP port 10BASE-T/100BASE-TX

Length of a twisted pair segment

100 m (328 ft) maximum

Interfaces

5 TP ports 

M12 sockets (4-pin, D coding), 10/100 MBit/s

Displays

Equipment status

1 x green LED 

P

– power, supply voltage present

Port status

5 x green LEDs 

DA/STAT

– data, link status

Scope of delivery

IP67 Switch OCTOPUS 5TX-EEC incl.

covers for sealing unused ports
labels, description and operating instructions

Order number

IP67 Switch OCTOPUS 5TX-EEC

943 892-001

IP67 Switch OCTOPUS 5TX-EEC with QoS 942 052-001

Accessories

Pocket Guide

280 710-851

Hirschmann Automation and Control GmbH
Stuttgarter Straße 45-51
D-72654 Neckartenzlingen
Germany
Tel.: ++49 / 1805 / 14-1538
Fax: ++49 / 7127 / 14-1551
E-Mail: [email protected]
Internet: http://www.beldensolutions.com

Printed in Germany
Subject to alterations

Summary of Contents for OCTOPUS 5TX-EEC

Page 1: ...les have five 10 100 Mbit s twisted pair ports 10BASE T 100BASE TX shielded M12 connectors It is possible to connect up to five DTEs data terminal equipment or other TP TX network segments to these ports using twisted pair cabling The TP ports support auto negotiation autopolarity and autocrossing The IP67 switch conforms with protection class IP67 protection against shock and foreign particles du...

Page 2: ...ch must be observed to ensure your own per sonal safety and to avoid damage to devices and machinery The instructions are highlighted with a warning triangle and are shown as follows according to the degree of endan germent z Danger means that death serious injury or considerable damage to property will result if the appropriate safety measures are not taken z Warning means that death serious inju...

Page 3: ...ry to open the housing of the device 䡺 Make sure that the electrical installation meets local or nationally applicable safety regulations Open type UL listed product intended to be installed in a Type 1 or better enclosure Safety Guidelines Environment z Warning The device may only be operated in the listed ambient temperature range 䡺 The installation location is to be selec ted so as to ensure co...

Page 4: ... to terminal equipment which is switched off is likewise assessed as a line interrupt as the de energised bus coupler cannot transmit link test pulses Auto polarity exchange If the receive line pair is incorrectly connec ted RD and RD switched polarity is auto matically reversed Autonegotiation Autonegotiation is a procedure in which the switch automatically selects the operating mode of its 10 10...

Page 5: ...Connect the cable shield to the connector housing You only need one M12 M12 patch cable version Fig 6 Patch cables for operating the OCTOPUS 5TX EEC RX TX RX TX Shield M12 MDI 1 2 3 4 S TX RX TX RX Shield M12 1 2 3 4 S RX RX TX TX Shield RJ45 MDI X 1 2 3 6 S TX RX TX RX Shield M12 1 2 3 4 S TX TX RX RX Shield RJ45 MDI 1 2 3 6 S TX RX TX RX Shield M12 1 2 3 4 S 4 3 2 1 Connection M12 M12 MDI X Conn...

Page 6: ...est level 2 Air discharge EN 61000 4 2 Test level 3 Electromagnetic fields EN 61000 4 3 Test level 3 Fast transients EN 61000 4 4 Test level 3 Surge voltage symmetrical EN 61000 4 5 Test level 2 Surge voltage asymmetrical EN 61000 4 5 Test level 3 Cable based RF faults EN 61000 4 6 Test level 3 EMC emitted immunity EN 55022 Class A FCC 47 CFR Part 15 Class A Stability Vibration IEC 60068 2 6 Test ...