background image

2

The performance features described here
are binding only if they have been expressly
guaranteed in the contract. We have
checked that the contents of the technical
publication agree with the hardware and
software described. However, it is not possi-
ble to rule out deviations completely, so we
are unable to guarantee complete agree-
ment. However, the details in the technical
publication are checked regularly. Any cor-
rections which prove necessary are contai-
ned in subsequent editions. We are grateful
for suggestions for improvement.

We reserve the right to make technical
modifications.

Permission is not given for the circulation
or reproduction of this document, its use or
the passing on of its contents unless gran-
ted expressly. Contravention renders the
perpetrator liable for compensation for
damages. All rights reserved, in particular
in the case of patent grant or registration of
a utility or design.

Copyright 
© Hirschmann 
Automation and Control GmbH 2011
All Rights Reserved

Note

We would point out that the content of
these operating instructions is not part of,
nor is it intended to amend an earlier or exi-
sting agreement, permit or legal relation-
ship. All obligations on Hirschmann arise
from the respective purchasing agreement
which also contains the full warranty condi-
tions which have sole applicability. These
contractual warranty conditions are neither
extended nor restricted by comments in
these operating instructions.

We would furthermore point out that for
reasons of simplicity, these operating
instructions cannot describe every
 conceivable problem associated with the
use of this equipment. Should you require
further information or should particular
 problems occur which are not treated in
sufficient detail in the operating instruc-
tions, you can request the necessary infor-
mation from your local Hirschmann sales
partner or directly from the Hirschmann
office (address: refer to chapter entitled
„Notes on CE identification“).

Safety Instructions

This manual contains instructions which
must be observed to ensure your own per-
sonal safety and to avoid 
damage to devices and machinery. The
instructions are highlighted with a warning
triangle and are shown as 
follows  according to the degree of endan-
germent:

z

Danger!

means that death, serious injury or
considerable damage to property

will

result if the appropriate safety

measures are not taken.

z

Warning!

means that death, serious injury or
considerable damage to property

can

result if the appropriate safety

measures are not taken.

z

Caution!

means that light injury or damage to
property can result if the appropria-
te safety measures are not taken.

Note:

is an important piece of information

about the product, how to use the product,
or the relevant  section of the documentati-
on to which particular attention is to be
drawn. 

Certified usage

Please observe the following:

z

Warning

The device may only be employed
for the purposes described in the
catalog and technical description,
and only in conjunction with external
devices and components recommen-
ded or approved by Hirschmann.
The product can only be operated
correctly and safely if it is transpor-
ted, stored, installed and assembled
properly and correctly. Furthermore,
it must be operated and serviced
carefully.

Safety Guidelines
Power Supply

z

Warning!

The devices may only be connected
to the supply voltage shown on the
type plate.

The devices are designed for opera-
tion with a safety extra-low voltage.
Thus, they may only be connected
to the supply voltage connections
with PELV circuits or  alternatively
SELV circuits with the  voltage
restrictions in accordance with
IEC/EN 60950-1.

For the case where the module is opera-

ted with external power supply: Use only a
safety extra-low voltage in accordance with
IEC/EN 60950-1 to power the system.

First of all you connect the ground

connection, before you establish the further
connections. When you remove connec-
tions, you disconnect the ground connec-
tion last.

The device does not contain any service

components. If the device is not functioning
correctly, or if it is damaged, switch off the
voltage supply and return the device to the
plant for inspection.

Fig. 1: Drilling template for assembling the OCTOPUS 5TX-EEC (dimensions in mm)

Summary of Contents for OCTOPUS 5TX-EEC

Page 1: ...les have five 10 100 Mbit s twisted pair ports 10BASE T 100BASE TX shielded M12 connectors It is possible to connect up to five DTEs data terminal equipment or other TP TX network segments to these ports using twisted pair cabling The TP ports support auto negotiation autopolarity and autocrossing The IP67 switch conforms with protection class IP67 protection against shock and foreign particles du...

Page 2: ...ch must be observed to ensure your own per sonal safety and to avoid damage to devices and machinery The instructions are highlighted with a warning triangle and are shown as follows according to the degree of endan germent z Danger means that death serious injury or considerable damage to property will result if the appropriate safety measures are not taken z Warning means that death serious inju...

Page 3: ...ry to open the housing of the device 䡺 Make sure that the electrical installation meets local or nationally applicable safety regulations Open type UL listed product intended to be installed in a Type 1 or better enclosure Safety Guidelines Environment z Warning The device may only be operated in the listed ambient temperature range 䡺 The installation location is to be selec ted so as to ensure co...

Page 4: ... to terminal equipment which is switched off is likewise assessed as a line interrupt as the de energised bus coupler cannot transmit link test pulses Auto polarity exchange If the receive line pair is incorrectly connec ted RD and RD switched polarity is auto matically reversed Autonegotiation Autonegotiation is a procedure in which the switch automatically selects the operating mode of its 10 10...

Page 5: ...Connect the cable shield to the connector housing You only need one M12 M12 patch cable version Fig 6 Patch cables for operating the OCTOPUS 5TX EEC RX TX RX TX Shield M12 MDI 1 2 3 4 S TX RX TX RX Shield M12 1 2 3 4 S RX RX TX TX Shield RJ45 MDI X 1 2 3 6 S TX RX TX RX Shield M12 1 2 3 4 S TX TX RX RX Shield RJ45 MDI 1 2 3 6 S TX RX TX RX Shield M12 1 2 3 4 S 4 3 2 1 Connection M12 M12 MDI X Conn...

Page 6: ...est level 2 Air discharge EN 61000 4 2 Test level 3 Electromagnetic fields EN 61000 4 3 Test level 3 Fast transients EN 61000 4 4 Test level 3 Surge voltage symmetrical EN 61000 4 5 Test level 2 Surge voltage asymmetrical EN 61000 4 5 Test level 3 Cable based RF faults EN 61000 4 6 Test level 3 EMC emitted immunity EN 55022 Class A FCC 47 CFR Part 15 Class A Stability Vibration IEC 60068 2 6 Test ...

Reviews: