background image

3

z

Warning!

Failure to observe the information
given in the warnings could result in
serious injury and/or major damage.

Only personnel that have received
appropriate training should operate
this device or work in its immediate
vicinity. The personnel must be fully
familiar with all of the warnings and
maintenance measures in these
operating instructions.

Correct transport, storage, and
assembly as well as careful operati-
on and maintenance are essential in
ensuring safe and reliable operation
of this device.

Use only undamaged parts!

These products are only to be used in

the manner indicated in this version of the
”Description and Operating Instructions”.

Particular attention is to be paid to all

warnings and items of information relating
to safety.

z

Warning!

Any work that may have to be per-
formed on the electrical installation
should be performed by fully quali-
fied technicians only.

Based specifications and 
standards:

The devices fulfil the following
 specifications and standards: 
– EN 61000-6-2:2005 – Generic standards –

Immunity for industrial environments

– EN 55022:2006 + A1:2007 – Information

technology equipment – Radio disturban-
ce  characteristics

– EN 60950-1:2006 – Safety of Information

Technology Equipment (ITE)

– EN 61131-2:2007 –  Programmable 

Controllers

– FCC 47 CFR Part 15:2009 – 

Code of Federal Regulations

– cUL 508:1998 – Underwriters Labratories

Inc. Safety for Industrial Control
 Equipment.

The device has a certification based on a
specific standard only if the certification
indicator appears on the housing.

7

Notes on CE 
identification

The devices comply with the regula-
tions of the following European
directive:

2004/108/EC
Directive of the European Parlia-
ment and of the Council on the
approximation of the laws of the
member states relating to electro-
magnetic compatibility.

The EU declaration of conformity is
kept available for the responsible
authorities in accordance with the
above-mentioned EU directives at:

Hirschmann 
Automation and Control GmbH 
Stuttgarter Straße 45-51
D-72654 Neckartenzlingen
Tel+49-1805-14-1538

Relevant for North America:

The subject unit is to be suppplied by a
Class 2 power source complying with the
requirements of the National Electrical
Code, table 11(b). If power is redundant
supplied (two individual power sources) the
power sources together should comply with
the requirements of the National Electrical
Code, table 11 (b).

Relevant for North America:

Use 60/75°C or 75°C copper(CU)wire only.

Safety Guidelines
Shielding Ground

Note:

The shielding of the twisted pair

wires which can be connected must be 
grounded on the plug housing.

Beware of possible short circuits when

connecting a cable section with conductive
shielding braiding.

Safety Guidelines Housing

z

Warning!

Do not try to open the housing of
the device.

Make sure that the electrical installation

meets local or nationally applicable safety
regulations.

Open type UL listed product – intended to
be installed in a Type 1 or better enclosure.

Safety Guidelines Environment

z

Warning!

The device may only be operated in
the listed ambient temperature
range.

The installation location is to be selec-

ted so as to ensure compliance with the cli-
matic limits listed in the Technical Data.

Staff qualification
 requirements

Note: 

Qualified personnel, as understood

in this manual and in the warning signs, are
persons who are familiar with the setup,
assembly, startup,  and operation of this
product and are appropriately qualified for
their job. This includes, for example, those
persons who have been:

– trained or directed or authorized to

switch on and off, to ground and to label
power circuits and devices or systems in
accordance with current safety enginee-
ring standards

– trained or directed in the care and use of

appropriate safety equipment in accor-
dance with the current standards of safety
engineering

– trained in providing first aid.

General Safety Instructions

This device is electrically operated.

Adhere strictly to the safety requirements
relating to voltages applied to the device as
described in the operating instructions!

The product can be used in the indu-
strial sphere.
– Interference immunity: 

EN 61000-6-2:2005

– Radio interference level: 

EN 55022:2006 + A1:2007,  Class A

z

Warning!

This is a Class A device. This equip-
ment may cause radio interference if
used in a residential area; in this
case it is the operator´s responsibili-
ty to take appropriate measures.

The precondition for compliance
with EMC limit values is strict adhe-
rence to the construction guidelines
specified in this description and
operating  instructions.

FCC Note:

This device complies with part 15 of FCC
rules. Operation is subject to the following
two conditions : (1) This device may not
cause harmful interference; (2) this device
must accept any interference received,
including interference that may cause unde-
sired operation.
This equipment has been tested and found
to comply with the limits for a Class A digi-
tal device, persuant to part 15 of the FCC
Rules. These limits are designed to provide
reasonable protection against harmful inter-
ference when the equipment is operated in
a commercial environment. This equipment
generates, uses, and can radiate radio fre-
quency energy and, if not installed and
used in accordance with the instruction
manual, may cause harmful interference to
radio communications. Operation of this
equipment in a residential area is likely to
cause harmful interference in which case
the user will be required to correct the inter-
ference at his own expense.

,

Recycling Note:

After its use, this product has to be
processed as electronic scrap and
disposed of according to the prevai-
ling waste disposal regulations of
your  community, district, country and
state.

Summary of Contents for OCTOPUS 5TX-EEC

Page 1: ...les have five 10 100 Mbit s twisted pair ports 10BASE T 100BASE TX shielded M12 connectors It is possible to connect up to five DTEs data terminal equipment or other TP TX network segments to these ports using twisted pair cabling The TP ports support auto negotiation autopolarity and autocrossing The IP67 switch conforms with protection class IP67 protection against shock and foreign particles du...

Page 2: ...ch must be observed to ensure your own per sonal safety and to avoid damage to devices and machinery The instructions are highlighted with a warning triangle and are shown as follows according to the degree of endan germent z Danger means that death serious injury or considerable damage to property will result if the appropriate safety measures are not taken z Warning means that death serious inju...

Page 3: ...ry to open the housing of the device 䡺 Make sure that the electrical installation meets local or nationally applicable safety regulations Open type UL listed product intended to be installed in a Type 1 or better enclosure Safety Guidelines Environment z Warning The device may only be operated in the listed ambient temperature range 䡺 The installation location is to be selec ted so as to ensure co...

Page 4: ... to terminal equipment which is switched off is likewise assessed as a line interrupt as the de energised bus coupler cannot transmit link test pulses Auto polarity exchange If the receive line pair is incorrectly connec ted RD and RD switched polarity is auto matically reversed Autonegotiation Autonegotiation is a procedure in which the switch automatically selects the operating mode of its 10 10...

Page 5: ...Connect the cable shield to the connector housing You only need one M12 M12 patch cable version Fig 6 Patch cables for operating the OCTOPUS 5TX EEC RX TX RX TX Shield M12 MDI 1 2 3 4 S TX RX TX RX Shield M12 1 2 3 4 S RX RX TX TX Shield RJ45 MDI X 1 2 3 6 S TX RX TX RX Shield M12 1 2 3 4 S TX TX RX RX Shield RJ45 MDI 1 2 3 6 S TX RX TX RX Shield M12 1 2 3 4 S 4 3 2 1 Connection M12 M12 MDI X Conn...

Page 6: ...est level 2 Air discharge EN 61000 4 2 Test level 3 Electromagnetic fields EN 61000 4 3 Test level 3 Fast transients EN 61000 4 4 Test level 3 Surge voltage symmetrical EN 61000 4 5 Test level 2 Surge voltage asymmetrical EN 61000 4 5 Test level 3 Cable based RF faults EN 61000 4 6 Test level 3 EMC emitted immunity EN 55022 Class A FCC 47 CFR Part 15 Class A Stability Vibration IEC 60068 2 6 Test ...

Reviews: