3. Assembly, startup procedure

and dismantling

3.1 UNPACKING, CHECKING

Check whether the package was deliver-
ed complete (see scope of delivery).

Check the individual parts for transport
damage.

z

Warning!

Use only undamaged parts!

3.2 ASSEMBLY

The equipment is delivered in a ready-to-
operate condition. 

To protect the exposed contacts of the com-
ponents still to be installed from dirt, the
individual system components must be
connected in a dry and clean area.

Ports which are not assigned are to be 
closed with the covering caps contained in
the scope of delivery.

Note: 

Connectors are not electrical isola-

ting devices. Therefore, first plug the
connector to the power supply plug and
then switch on the power supply.

The following sequence is the best for
assembly:

Prepare assembly at the installation site:
drill holes at the installation site

Mechanical assembly at the installation
site

Electrical connection with peripheral
devices

Connect the signal lines with the twisted
pair ports

Assembly:

– Fit the module on a level surface with

three M4x16 screws.

– Provide a low impedance ground connec-

tion via the clips at the screen plate, either
by mounting directly on a conductive sur-
face or by the additional connection of a
ground wire to a fastening strap on the
screen plate. Use toothed locking washers
for a good electrical connection.

– Voltage supply

: The  supply voltage is

electrically isolated from the housing.

Ground

The device is grounded via the fixing screws
of the chassis or via the pin 5 of the power
supply connector.
We recommend the grounding via the fixing
screws.

2. Configuration

2.1 CONNECTING DTE AND OTHER
NETWORK SEGMENTS

It is possible to connect up to five data ter-
minal equipment (DTE) or other network
segments to the 10/100 Mbit/s ports of the
OCTOPUS 5TX-EEC using twisted pair cab-
ling (ref. Fig. 5).

2.2 PATCH CABLES

To operate the IP67 switch, use patch cables
as shown in Figs. 5 and 6.

Notes: 

– Use a shielded CAT5 cable.

– Use a shielded 4-pin M12 connector.

– Connect the cable shield to the connector

housing.

– You only need one M12-M12 patch cable

version.

Fig. 6: Patch cables for operating the 
OCTOPUS 5TX-EEC 

RX+
TX+
RX-
TX-

Shield

M12, MDI

1
2
3
4

S

TX+

RX+

TX-

RX-

Shield

M12

1
2
3
4

S

RX+
RX-
TX+
TX-

Shield

RJ45, MDI-X

1
2
3
6

S

TX+

RX+

TX-

RX-

Shield

M12

1
2
3
4

S

TX+
TX-
RX+
RX-

Shield

RJ45, MDI

1
2
3
6

S

TX+

RX+

TX-

RX-

Shield

M12

1
2
3
4

S

4

3

2

1

Connection M12 <-> M12, MDI-X

Connection M12 <-> M12, MDI

Connection M12 <-> RJ45, MDI-X

Connection M12 <-> RJ45, MDI

2

3

4

TX+
RX+
TX-
RX-

Shield

M12, MDI-X

1
2
3
4

S

TX+

RX+

TX-

RX-

Shield

M12

1
2
3
4

S

1

A drilling template at a scale of 1:1 for 
marking the drilling holes can be found on
page 2, Fig. 1.

Connection:

– The protection class IP67 is only achieved

when bolted together.

– Empty slots must be sealed with the pro-

tective caps supplied.

Notes on wiring:

In keeping with the general installation
regulations, ensure that the signal and
power lines > 60 V are laid separately (cable
duct, clamps). The signal and 24 V supply
voltage lines should be laid off the module
as straight as possible.

Notes on strain relief:

Provide sufficient strain relief and secure
cable fastening for all connected wiring.

3.3 STARTUP PROCEDURE

You start up the OCTOPUS 5TX-EEC by

connecting the supply voltage via the 5-pin
M12 connector.

4. Further support

In the event of technical queries, please talk
to the Hirschmann contract partner respon-
sible for looking after your account or
 directly to the Hirschmann office. You can
find the addresses of our contract partners
on the Internet: 
www.beldensolutions.com.

Our support line is also at your disposal:
Tel. +49(1805) 14-1538
Fax +49(7127) 14-1551

Answers to Frequently Asked Questions can
be found on the Hirschmann internet site
(www.beldensolutions.com) at the end of
the product sites in the FAQ category.
The current training courses to technology
and products can be found under
www.hicomcenter.com.

Fig. 5: Possible network configuration with the IP67 switch OCTOPUS 5TX-EEC

1

1

Rail switch,

e.g. RS2-5TX

x

RS2-5TX

i

X

1
2 3
4 5

IP67 switch

OCTOPUS

Data terminal

device

SPS

IP67 switch

OCTOPUS

OCTOPUS 5TX

DA/STAT

DA/STAT

DA/STAT

DA/STAT

P

DA/STAT

OCTOPUS 5TX

DA/STAT

DA/STAT

DA/STAT

DA/STAT

P

DA/STAT

2

or

3

2

or

3

Summary of Contents for OCTOPUS 5TX-EEC

Page 1: ...les have five 10 100 Mbit s twisted pair ports 10BASE T 100BASE TX shielded M12 connectors It is possible to connect up to five DTEs data terminal equipment or other TP TX network segments to these ports using twisted pair cabling The TP ports support auto negotiation autopolarity and autocrossing The IP67 switch conforms with protection class IP67 protection against shock and foreign particles du...

Page 2: ...ch must be observed to ensure your own per sonal safety and to avoid damage to devices and machinery The instructions are highlighted with a warning triangle and are shown as follows according to the degree of endan germent z Danger means that death serious injury or considerable damage to property will result if the appropriate safety measures are not taken z Warning means that death serious inju...

Page 3: ...ry to open the housing of the device 䡺 Make sure that the electrical installation meets local or nationally applicable safety regulations Open type UL listed product intended to be installed in a Type 1 or better enclosure Safety Guidelines Environment z Warning The device may only be operated in the listed ambient temperature range 䡺 The installation location is to be selec ted so as to ensure co...

Page 4: ... to terminal equipment which is switched off is likewise assessed as a line interrupt as the de energised bus coupler cannot transmit link test pulses Auto polarity exchange If the receive line pair is incorrectly connec ted RD and RD switched polarity is auto matically reversed Autonegotiation Autonegotiation is a procedure in which the switch automatically selects the operating mode of its 10 10...

Page 5: ...Connect the cable shield to the connector housing You only need one M12 M12 patch cable version Fig 6 Patch cables for operating the OCTOPUS 5TX EEC RX TX RX TX Shield M12 MDI 1 2 3 4 S TX RX TX RX Shield M12 1 2 3 4 S RX RX TX TX Shield RJ45 MDI X 1 2 3 6 S TX RX TX RX Shield M12 1 2 3 4 S TX TX RX RX Shield RJ45 MDI 1 2 3 6 S TX RX TX RX Shield M12 1 2 3 4 S 4 3 2 1 Connection M12 M12 MDI X Conn...

Page 6: ...est level 2 Air discharge EN 61000 4 2 Test level 3 Electromagnetic fields EN 61000 4 3 Test level 3 Fast transients EN 61000 4 4 Test level 3 Surge voltage symmetrical EN 61000 4 5 Test level 2 Surge voltage asymmetrical EN 61000 4 5 Test level 3 Cable based RF faults EN 61000 4 6 Test level 3 EMC emitted immunity EN 55022 Class A FCC 47 CFR Part 15 Class A Stability Vibration IEC 60068 2 6 Test ...

Reviews: