Ring Redundancy
18
2.1 Example of a HIPER-Ring
Redundancy
Release 6.0 07/2010
Display in “Operation” field:
–
active
: This port is switched on and has a link.
–
inactive
: This port is switched off or it has no link.
Figure 4: Ring Redundancy dialog
Activate the ring manager for this device. Do not activate the ring
manager for any other device in the HIPER-Ring.
In the “Ring Recovery” frame, select the value “Standard” (default).
Note:
Settings in the “Ring Recovery” frame only take effect for devices
configured as ring managers.
Click “Set” to temporarily save the entry in the configuration.