• The unit must be used exclusively in accordance with intended use and in a technically safe condition! The operational safety of the unit is only guaranteed if it is used for its
intended purpose. Failure to comply with the individually listed points in the operating instructions can result in physical injury or material damage for which the manufactu-
rer assumes no liability.
• Keep all safety and danger notices on/at the unit complete and always in a legible condition.
• The maintenance intervals specified in these operating instructions must be observed.
• Only use genuine spare parts.
• If the
mains cable
for this device is damaged, then to avoid risk the cable must be replaced by the manufacturer, its customer service team, or a similarly qualified person.
3. Residual risks and foreseeable misuse
Risks for persons:
under the following circumstances, the safety of persons and material objects can be endangered:
• Troubleshooting, adjustment, cleaning, repair and maintenance work contrary to the instructions in the operating instructions.
• If untrained personnel are working on electronic parts.
• Failure to comply with the safety instructions in the operating instructions.
• Unauthorised modifications to the unit.
• Use of non-original manufacturer spare parts.
The following points summarise further measures aimed at protecting against personal and material risks:
• Mount the unit in a place that is well ventilated and free from electromagnetic interference.
Risk for animals:
• The animals are not yet accustomed to using the inhaler (risk of panic reaction).
• The animals are unsupervised during use.
• The animals are not tethered correctly to the site.
4. Description
4.1 Description of the unit
Ultrasound Inhaler for Horses
The devices are designed to split (nebulise) inhalants by ultrasound into components small enough for them to be optimally absorbed by the horse through inhalation. The
choice of inhalant is the operator's responsibility.
Caution!
The unit must be used exclusively in accordance with intended use and in a technically safe condition! The operational safety of the unit is only guaranteed if it is used for its
intended purpose. Failure to comply with the individually listed points in the operating instructions can result in physical injury or material damage for which the manufactu-
rer assumes no liability.
4.2 Scope of delivery
The AirOne ultrasound inhaler is made up of the following components:
1. Ultrasound unit incl. mains connection cable
2. Nebulising chamber (fixed component of the nebuliser)
3. Removable nebulising chamber cover with connecting pieces (3.1)
4. Breathing mask with connecting pieces (4.1), adjustable fresh air supply (4.2), rubber seal (4.3), adjustable head strap (4.4) and one inhalation (4.5) and two removable
exhalation valves (4.6)
5. Breathing tube
6. Wall bracket with 4 screws, 4 dowels and installation instructions
7. Transport box with cover (not shown)
The accessories also include:
a measuring cup, 30 nebuliser cups, 1 litre of contact liquid.