23
_____________________________________________________________________________________________
Chapter 4 Using WAVE COMMUNICATOR
______________________________________________________________________________________________
4.7 Sending Setting Files
This function sends a setting file to the MEMORY HiCORDER units,
changing their settings.
The setting data is transferred in the same format as the file saved on the
MEMORY HiCORDER. After modifying a setting file from the
MEMORY HiCORDER using the Settings Editor, you can return it to the
MEMORY HiCORDER, to update the settings . (File extension .set )
You can also send a setting file newly created with the Settings Editor. For
more details of creating setting files, see Chapter 6, "Creating and
Modifying Setting Files."
The same setting file is transferred to all connections in the list. If you do
not need to send the setting file to a device, double-click the device in the
list, and change the communications setting to "off".
If you have
Modem
selected in the communications settings, then any
connections set to
COM1
or
COM2
will be ignored when transferring data.
Similarly, if the communications setting is
Direct
, no data will be
transferred to connections set to
Modem
.
If the MEMORY HiCORDER is in the process of measurement, this is
stopped automatically before sending the setting file. To restart
measurement after transferring the setting file, change the settings in the
connections, by checking the "
Start measurement at end of
communications
" check box.
Transferring the setting file
1. Select
Communications - Settings File - Send
.
2. You will be prompted, asking whether it is OK to stop measurement on
the MEMORY HiCORDER. If so, click
OK
. If there is a connection which
you do not want to stop, click
Cancel
, and change the communications
setting to "off".
3. The
Select File
dialog box appears. Select the setting file (file extension:
.set ) and click
Open
.
4. The communications operation starts.
5. If communications are interrupted, click
Cancel
. In this case, the
communications with the current connection are abandoned, and
communications with the next connection starts.
6. If no MEMORY HiCORDER is found on a connection, or if
communications error occurs, then a dialog box appears to indicate the
communications problem. Click
OK
to start the next connection.
7. When the setting file has been sent to all of the connections, a dialog box
for ending communications appears. Click
OK
to end communications.
Summary of Contents for 9332
Page 1: ...INSTRUCTION MANUAL 9332 WAVE COMMUNICATOR ...
Page 2: ......