46
PROTEC5X - User’s manual
4.4
Zones operating
The four protection zones have different operating features.
4.4.1
Zone 1 (delayed)
!
On system enabled, the opening of NC line activates an alarm cycle, after the entering
time setted in programming (par. 3.5).
!
The time of the alarm cycle is setted in programming.
!
If the NC line is not restored it autoexcludes after 3 alarm cycles.
!
At the restoring of the NC line the zone is reincluded in service.
!
It can be exclued by the user by the button on the front panel or by electronic key.
It is advisable to use this zone for the NC lines made by magnetic contacts placed on the
entrance door/s. The entering time allows to enter from these entrances and to arrive at the
central unit to disable the system. If an SKI connector is installed outside of the entrance door, it
is advisable to program the minimum enering time.
4.4.2
Zone 2 (immediated)
!
On system enabled, the opening of NC line activates an alarm cycle.
!
The time of the alarm cycle is setted in programming.
!
If the NC line is not restored it autoexcludes after 3 alarm cycles.
!
At the restoring of the NC line the zone is reincluded in service.
!
It can be exclued by the user by the button on the front panel or by electronic key.
It is advisable to use this zone for the NC lines made by volumetric detectors . The
possibility to disable this zone by panel or electronic key, will allow the partial system operating
(ex. in the night zones giving the possibility to move liberally in the rooms leaving the others
protection zonesenabled).
4.4.3
Zone 3 (immediated)
!
On system enabled, the opening of NC line activates an alarm cycle.
!
The time of the alarm cycle is setted in programming.
!
If the NC line is not restored it autoexcludes after 3 alarm cycles.
!
At the restoring of the NC line the zone is reincluded in service.
!
It can be exclued by the user by the button on the front panel or by electronic key.
It is advisable to use this zone for the NC lines made by magnetic contacts.
4.4.4
Zone 24h (immediated)
!
On system disabled, the opening of NC line activates a continuous alarm cycle. It will stop
at the line restoring.
!
On system enabled, the opening of NC line activates an alarm cycle.
!
The time of the alarm cycle is setted in programming.
!
If the NC line is not restored, the zone autoexcludes.
This line is made by a series of antiopening and antitearing tampers inside of the system
devices.
4.5
Alarm memory
With the system disabled,pressing the "MEMORY ALARM" key, the zones control LEDs
show thezones zones and the zones have caused the alarm.
LED on
zone autoinhibited
LED blinking
zone has caused the last alarm
5.1
Battery
It is advisable to check the battery connected to the power supplier/battery charger and
the battery inside of the self-powered sirens.
5.2
Cleaning
For the central unit cleaning, use only a soft and humid cloth.
Do not use absolutely diluents and abrasive sponges.
5.3
Fuses
F1 Sirens output
F type
3A
F2 Services output
F type
1A
5
Maintenance
47
Operating
security
security