4.3
Excluding the zones
It is possible to exclude the zones that we don't want to be protected during the system
enabling.
For example, during the night hours we can exclude the zone of the volumetric detectors
and leave included the zone with the perimetral protection (access doors, windows) in the way
to move inside of the protected area.
4.3.1
Excluding the zones from the front panel
On system disabled, press the button relative to the zone that we want to exclude during
the system enabling.
The zone relative LED turns on with short flashes.
NOTE: if the zone is opened and the relative LED is on, at the exclusion of the zone the
LED turns off with short flashes.
4.3.2
Excluding the zones from the electronic key
At the moment of the system enabling, it is possible to disable the zones 1 and 2 directly
from the electronic key:
!
Insert the key in the connector and leave it in.
!
The LEDs on the connector will turn on following the order shown in the table below:
!
Extract the key when the desided condition is verified.
44
45
Operating
PROTEC5X - User’s manual
4.2
System enabling /disabling
4.2.1
Enabling
!
Insert the electronic key in the connector and extract it immediately. Leaving the key in the
connector will start the exclusion of the zones (par. 4.3.2).
!
The green LED starts blinking indicating the exiting time.
!
After the exiting time, the green LED starts emitting flashes to indicate that the system is
enabled.
4.2.2
Disabling
!
Insert the electronic key in the connector and extract it after that the green LED turns on.
!
On emergency, if the electronic keys are lost, the system can be disabled pressing for 45
seconds the PROGRAM key inside of the central unit.
SKI/NL
(Additional
connector)
GREEN LED
RED LED
GREEN
LED
RED
LED
Zone 2 excluded
Zone 1 excluded
Zones 1 and 2 excluded
None zone excluded
CONDITION
security