42
43
Operating
PROTEC5X - User’s manual
4
Operating
4.1
Front panel description
4
5
3
1
2
Green LED - System status control
LED on
system disabled
LED blinking
during the exiting time
LED flashing
system enabled
Red LED - Zone status control
On system disabled and during the exiting time:
LED on
one or more opened zones
LED blinking
one or more excluded zones
On system enabled:
LED blinking
alarm memory
Red LEDs - Zone 1, zone 2, zone 3 status control
LED on
zone opened
LED off
zone closed
LED blinking
zone excluded
Zones exclusion/inclusion buttons
On system disabled, it is possible to exclude a zone
pressing the relative zone button; the LED
corresponding to the zone excluded starts flashing.
Pressing again the button the zone is included and the
LED stops with flashing.
Note: if the zone is opened, the LED will be turned on,
and the flash will be reversed, that is the flash will turn
off the LED for a moment.
Red LED - Zone 24h status control
LED on
zone
opened
LED off
zone closed
LED blinking
zone autoexcluded
Alarm Memory / Autoinhibited Zones visualization
button
On system disabled, pressing this button, the status
control LEDs indicate:
LED on
zone autoinhibited
LED blinking
zone that caused the alarm
(Alarm Memory)
Yellow LED - Power supply status control
LED on
power supply OK
LED blinking
overloaded power supply
Red LED - Fuses status control
LED on
fuses OK
LED blinking
at least one fuse interrupted
Green LED - Main power supply status control
LED on
main power supply present
LED blinking
main power supply absent
10
11
12
13
1
2
3
4
5
6
7
8
9
o
N
main power
fuse
power supply
e x c l u s i o n
opened
disarmed
system
zone
lamp.
lamp.
EXIT
ACCESS
alarm
memory
flash
flash
arm
zone
system
exclused
allarme
memoria
alarm
memory
ZONE CONTROL
green
red
led
acceso
led
impianto
zone
disinserito
aperte
uscita
entrata
allarme
memoria
impianto
zone
inserito
escluse
verde
rosso
o
N
main power
fuse
power supply
e x c l u s i o n
opened
disarmed
system
zone
lamp.
lamp.
EXIT
ACCESS
alarm
memory
flash
flash
arm
zone
system
exclused
allarme
memoria
alarm
memory
ZONE CONTROL
green
red
led
acceso
led
impianto
zone
disinserito
aperte
uscita
entrata
allarme
memoria
impianto
zone
inserito
escluse
verde
rosso
12V
Int
24h
A
B
C
D
RIT IMM
COM.
IMM2
COM. SIR. S.A.
9
10
11
12
13
6
7
8
3.8
Alarm system abilitation in absence of net
This option is for the activation of a series of alarm of few second after 5 hours of absence
Of the net..
!
Disconnecting the system..
!
Pressing the PROGRAM key up to the flashing of LEDs .
!
Pressing the key for enable/disable the option.
!
The flashing of LED will point out the abilitation of the function.
!
Pressing three consecutive times the key to log out of the programming.
1
3
4
5
8
1
2
7
6
4
5
3
o
N
main power
fuse
power supply
e x c l u s i o n
opened
disarmed
system
zone
lamp.
lamp.
EXIT
ACCESS
alarm
memory
flash
flash
arm
zone
system
exclused
allarme
memoria
alarm
memory
ZONE CONTROL
green
red
led
acceso
led
impianto
zone
disinserito
aperte
uscita
entrata
allarme
memoria
impianto
zone
inserito
escluse
verde
rosso
o
N
main power
fuse
power supply
e x c l u s i o n
opened
disarmed
system
zone
lamp.
lamp.
EXIT
ACCESS
alarm
memory
flash
flash
arm
zone
system
exclused
allarme
memoria
alarm
memory
ZONE CONTROL
green
red
led
acceso
led
impianto
zone
disinserito
aperte
uscita
entrata
allarme
memoria
impianto
zone
inserito
escluse
verde
rosso
12V
Int
24h
A
B
C
D
RIT IMM
COM.
IMM2
COM. SIR. S.A.
5X
PROTEC
5X
PROTEC
security