4 Technical data
Right of technical changes reserved.
Rated voltage
220…240 V
220...240V / CH
220...240V / GB
220...240V/NZ
36 V
Rated power
input
1,200 W
1,200 W
1,200 W
1,200 W
750 W
Maximum load
on built-in
power outlet for
electric tools
(if fitted)
2,000 W
700 W
1,400 W
800 W
Mains connec-
tion (type)
H07 RN‑F
3G 1.5 mm²
H07 RN‑F
3G 1.5 mm²
H07 RN‑F
3G 1.5 mm²
H07 RN‑F
3G 1.5 mm²
Power source
AC mains supply (230V)
Battery-powered operation
Max. air flow rate,
VC 20‑U-Y / VC 40‑U-Y
74 l/s
57 l/s
Max. air flow rate,
VC 20‑UM-Y / VC 40‑UM-Y
136 m³/h
106 m³/h
Max. vacuum, C 20‑U-Y / VC 40‑U-
Y
23 kPa
16.6 kPa
Max. vacuum VC 20‑UM-Y,
VC 40‑UM‑Y
22 kPa
15.6 kPa
Information about the appliance and its applications
Protection class
Protection class I
Protection class
IP X4 protection against sprayed water
Noise and vibration information (measured in accordance with EN 60335-2-69):
Typical A-weighted emission sound pressure level
71 dB (A)
Uncertainty for the given sound level
2.5 dB (A)
Triaxial vibration value (vibration vector sum)
< 2.5 m/s²
Uncertainty (K)
is taken into account in the vibration value
Appliance
VC 20‑U‑Y/ VC 20‑UM‑Y
VC 40‑U‑Y/ VC 40‑UM‑Y
Mains frequency
50 / 60 Hz
50 / 60 Hz
Weight in accordance with EPTA
procedure 01/2003
15.3 kg / 15.3 kg
16.9 kg / 16.9 kg
Weight of suction hose
1.3 kg
1.3 kg
Dimensions (L x W x H)
545 mm x 380 mm x 545 mm
530 mm x 380 mm x 675 mm
Supply cord
5 m
5 m
Container capacity
21 l
36 l
Effective dust capacity
23 kg
40 kg
Effective water capacity
13.5 l
25 l
Suction hose diameter (rotary con-
nector at nozzle end; connector at
vacuum cleaner end)
36 mm
36 mm
Air temperature
-10…+40°C
-10…+40°C
Automatic filter cleaning (can be
disabled) approx. every
15 s
15 s
en
24
Printed: 24.03.2014 | Doc-Nr: PUB / 5140202 / 000 / 03