background image

Beam

1 Flange Connection

(1) 5/16” x 3-1/2” Zinc Plated Lag Bolt

(1) Stainless steel washer

(1) 1 Flange Connector

End Clamp

(1) Stainless steel hex bolt

(1) Stainless steel flange nut

(1) Slider

(1) End Clamp

2 Flange Connection *

Shown without butyl option 

(2) #14   X 3” Concealor™ screws

(1) 2 Flange Connector

UGC-2 Grounding

Beam Splice **

Shown without grounding option

(2) Stainless steel hex bolt

(2) Stainless steel flange nut

(1) Beam Splice

Mid Clamp

(1) Stainless steel hex bolt

(1) Stainless steel flange nut

(1) Slider

(1) Mid Clamp

COMPONENTS

ADDITIONAL COMPONENTS

* Butyl (optional with 2 Flange Connection)

** WEEB 9.5 Grounding (optional with Grounding Splice Kit)

SolarMount-I 1.0 Beam = 1.094” Height 

 

144” Length

SolarMount-I 2.5 Beam = 2.5” Height

 

144” and 192” Lengths

Summary of Contents for UNIRAC SolarMount-I

Page 1: ...INSTALLATION MANUAL Pub 110518 1ii May 2011 2011 by Unirac Inc All rights reserved SolarMount I R A HILTI GROUP COMPANY 1411 Broadway Boulevard NE Albuquerque NM 87102 1545 USA...

Page 2: ...translated to another language without the prior written consent of Unirac Unirac Inc Marketing Department 1411 Broadway Boulevard NE Albuquerque NM 87102 1545 Unirac Inc 2011 All rights reserved SOLA...

Page 3: ...s 1 2 Flange Connector UGC 2 Grounding Beam Splice Shown without grounding option 2 Stainless steel hex bolt 2 Stainless steel flange nut 1 Beam Splice Mid Clamp 1 Stainless steel hex bolt 1 Stainless...

Page 4: ...3 4 Hex Head Bolt 1 3 8 x 1 3 4 EPDM Washer PV Quick Mount 1 5 16 x 3 1 2 Stainless Steel Lag Bolt 1 5 16 Sealing Washer 1 5 16 EPDM Washer 1 1 Flange Connection CreoTecc Tile Hook Top 2 5 16 x 3 1 2...

Page 5: ...he length of one module The length of the installation area is equal to The total width of the modules Plus 1 inch for each space between modules for mid clamp Plus 3 inches 1 inches for each pair of...

Page 6: ...e double wall side before clicking connection into beam NOTE Do not use connection if the engagement features on the connection are bent damaged or obstructed by debris 1 2 3 Beam NOTE When installing...

Page 7: ...en using 2 Flange Connection w Butyl Pad remove liner before installing screws 2 Flange Connection Option 1 Flange Connection Option Lag Bolt Concealor Screw Step 3 Install appropriate number of slide...

Page 8: ...Please refer to technical datasheets for recommended distances between splices NOTE Use anti seize on bolt and tighten nut to 10 foot pounds Step 4A Install Splices 1 Use when splicing two beams at a...

Page 9: ...Step 5 Installing Grounding Lugs Grounding Lug Step 6 Install modules using top mounting hardware NOTE Use anti seize on bolt and tighten nut to 10 foot pounds Module End Clamp Module Module Mid Clamp...

Page 10: ...irac com Warranty Information See http www unirac com for current warranty documents and information WARRANTY INSTALLATION MANUAL SolarMount I YOUR UNIRAC DISTRIBUTOR SOLIGENT 800 967 6917 www soligen...

Reviews: