8
English
2102963
*2102963*
If the device is powered by a generator or transformer, the generator or
transformer’s power output must be at least twice the rated input power
shown on the rating plate of the device. The operating voltage of the
transformer or generator must always be 5 % and -15 % of the rated
voltage of the device.
TE 50AVR
Weight (without supply cord)
13.4 lb
(6.1 kg)
Storage temperature
−4 ℉ … 158 ℉
(−20 ℃ …
70 ℃)
Ambient temperature for operation
1 ℉ … 140 ℉
(−17 ℃ …
60 ℃)
Ø hammer drill bits
1/2 in …
1 1/4 in
Ø hammer drill bits
12 mm …
32 mm
Ø drill bits for wood
1/4 in …
1 3/8 in
Ø drill bits for wood
6 mm … 35 mm
Ø drill bits for metal
1/4 in … 1/2 in
Ø drill bits for metal
6 mm … 13 mm
5
Operation
5.1 Preparations at the workplace
CAUTION
Risk of injury!
Inadvertent starting of the product.
▶
Unplug the supply cord before making adjustments to the power tool or
before changing accessories.
Observe the safety instructions and warnings in this documentation and on
the product.
5.1.1 Fitting the side handle
1. Release the side handle clamping band by turning the handle grip.
2. Slide the side handle clamping band over the chuck from the front and
into the recess provided.
3. Bring the side handle into the desired position.
4. Tighten the side handle clamping band by turning the handle grip.
Printed: 14.12.2018 | Doc-Nr: PUB / 5283567 / 000 / 03
Summary of Contents for TE 50
Page 2: ...1 Printed 14 12 2018 Doc Nr PUB 5283567 000 03 ...
Page 3: ...2 3 4 Printed 14 12 2018 Doc Nr PUB 5283567 000 03 ...
Page 4: ...5 6 7 8 Printed 14 12 2018 Doc Nr PUB 5283567 000 03 ...
Page 5: ...9 Printed 14 12 2018 Doc Nr PUB 5283567 000 03 ...
Page 61: ...Printed 14 12 2018 Doc Nr PUB 5283567 000 03 ...