4 Technical data
4.1 Technical data
Operating range
2 m … 30 m
Laser plane display accuracy (at 10m)
±1 mm (± 0.4 in)
Receiving area
120 mm (5 in)
Center indication from top edge of casing
75 mm (3 in)
Receiver automatic power-off
When no beam is detected: 30 min.
Dimensions
160 mm X 67 mm X 27 mm (6.5" X 2.6" X
0.9")
Weight (including batteries)
0.25 kg (0.6 lbs)
Power source
2 AA batteries
Operating temperature
-20…+50 °C (-4 to 122°F)
Storage temperature
-30…+60 °C (-22 to 140°F)
Protection class
IP 56, in accordance with IEC 529
5 Operation
5.1 Switching on and off
▶
Press the on / off button to switch the tool on or off.
5.2 Working with the receiver
▶
The PMA 31 G receiver can be used at distances of up to 35 m (115 ft) from the laser tool. The laser
beam is indicated visually and by a signal tone.
5.3 Working with the horizontal line
▶
Hold the PMA 31 G receiver in the laser beam with the receiving window at right angles to the projected
plane of the line.
Note
Results may be inaccurate if the receiving window is not held at right angles to the projected plane
of the line.
5.4 Working with the vertical line
1. Check that the vertical line is projected at right angles to the wall (or working surface).
Note
Results may be inaccurate if the vertical line is not projected at right angles to the wall or working
surface.
2. Switch the PMA 31 G receiver on by pressing the on/off button .
3. Hold the PMA 31 G receiver in the laser beam with the receiving window at right angles to the projected
plane of the line.
Note
Results may be inaccurate if the receiving window is not held at right angles to the projected plane
of the line.
5.5 Adjusting the volume
▶
Set the desired volume level by pressing the audible signal adjustment button.
5.6 Cleaning and drying
▶
Blow dust off the surface.
▶
Do not touch the display areas or the receiving window with your fingers.
▶
Use only a soft, clean cloth to clean the tool. If necessary, moisten the cloth with a little alcohol or water.
Printed: 02.05.2017 | Doc-Nr: PUB / 5343882 / 000 / 01
Summary of Contents for PMA 31-G
Page 2: ...1 Printed 02 05 2017 Doc Nr PUB 5343882 000 01...
Page 4: ...Printed 02 05 2017 Doc Nr PUB 5343882 000 01...
Page 147: ...143 Hilti Printed 02 05 2017 Doc Nr PUB 5343882 000 01...
Page 160: ...Printed 02 05 2017 Doc Nr PUB 5343882 000 01...
Page 161: ...Printed 02 05 2017 Doc Nr PUB 5343882 000 01...