
*2241313*
2241313
English
21
8
Transport and storage of cordless tools
Transport
CAUTION
Accidental starting during transport
!
▶
Always transport your products with the batteries removed!
▶
Remove the battery.
▶
Never transport batteries in bulk form (loose, unprotected).
▶
Check the tool and batteries for damage before use after long periods of transport.
Storage
CAUTION
Accidental damage caused by defective or leaking batteries
!
▶
Always store your products with the batteries removed!
▶
Store the tool and batteries in a place that is as cool and dry as possible.
▶
Never store batteries in direct sunlight, on heating units or behind a window pane.
▶
Store the tool and batteries in a place where they cannot be accessed by children or unauthorized
persons.
▶
Check the tool and batteries for damage before use after long periods of storage.
9
Troubleshooting
If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by
yourself, please contact
Hilti
Service.
9.1
Troubleshooting
Trouble or fault
Possible cause
Action to be taken
The battery runs down more
quickly than usual.
Very low ambient temperature.
▶
Allow the battery to warm up
slowly to room temperature.
The battery doesn’t engage
with an audible click.
The retaining lugs on the battery
are dirty.
▶
Clean the retaining lugs and refit
the battery.
1 LED flashes.
The device does not work.
Low battery.
▶
Change the battery and charge
the empty battery.
The battery is too hot or too cold.
▶
Allow the battery to cool down
or warm up slowly to room
temperature.
All 4 LEDs flash.
The device does not work.
The tool has been overloaded.
▶
Release the control switch and
then press it again. Then allow
the power tool to run under no
load for approx. 30 seconds.
The power tool or battery
gets very hot.
Electrical fault
▶
Switch the power tool off im-
mediately, remove the battery,
keep it under observation, allow
it to cool down and contact
Hilti
Service.
The tool does not achieve full
power.
A battery with inadequate capacity
was used.
▶
Use a battery with adequate
capacity.
The motor has no braking
effect.
Low battery.
▶
Change the battery and charge
the empty battery.
The power tool was overloaded
briefly.
▶
Switch the power tool off and
then on again.
10
RoHS (Restriction of Hazardous Substances)
Click on the link to go to the table of hazardous substances: qr.hilti.com/r9966169.
There is a link to the RoHS table, in the form of a QR code, at the end of this document.
Summary of Contents for GFB 6X-A22
Page 2: ...1...
Page 3: ...2 3 4 5...
Page 4: ...6 7...
Page 6: ......
Page 201: ......
Page 202: ......
Page 203: ......
Page 204: ...Hilti registered trademark of Hilti Corp Schaan Pos 1 20191021 2241313 2241313...