Hilti DX 462 Operating Instructions Manual Download Page 8

22

en

쎱쎱

8.4

Check the buffer and piston for wear

Replace the buffer if:

the metal ring is loose or broken,

the buffer no longer holds on the fastener guide,

excessive, uneven wear beneath the metal ring is

noticed.
Replace the piston if:

it is broken,

the tip is heavily worn (i.e. a 90° segment is chipped

off),

piston rings are broken or missing,

it is bent (check by rolling on an even surface).

NOTE

Do not use worn pistons. Do not modify or grind pis-
tons.

쎱쎱

8.5

Cleaning the piston rings

1. Use the flat brush to clean the piston rings.
2. Spray the piston rings lightly with Hilti spray.

쎱쎱

8.6

Clean the threaded section of the fastener guide

1. Clean the thread with the flat brush.
2. Spray the thread lightly with Hilti spray.

쎱쎱

8.7

Disassemble the piston return unit

1. Press the release button at the gripping part.
2. Unscrew the piston return unit.

쎱쎱

8.8

Clean the piston return unit

1. Clean the spring with the flat brush.
2. Clean the front end with the flat brush.
3. Use the small round brush to clean the two holes at

the end face.

4. Use the large round brush to clean the large hole.
5. Spray the piston return unit lightly with Hilti spray.

쎱쎱

8.9

Clean inside the housing

1. Use the large round brush to clean inside the hous-

ing.

2. Spray the inside of the housing lightly with Hilti

spray.

쎱쎱

8.10

Clean the cartridge strip guideway

Use the scraper provided to clean the right and left car-
tridge strip guideways. The rubber cover must be lifted
slightly to facilitate cleaning of the guideway.

쎱쎱

8.11

Spray the power regulation wheel lightly with

Hilti spray.

쎱쎱

8.12

Fit the piston return unit

1. Bring the arrows on the housing and on the exhaust

gas piston return unit into alignment.

2. Push the piston return unit into the housing as far as

it will go.

3. Screw the piston return unit onto the tool until it

engages.

쎱쎱

8.13

Assemble the tool

1. Push the piston into the tool as far as it will go.
2. Press the buffer onto the fastener guide until it snaps

into place.

3. Press the fastener guide firmly onto the piston return

unit.

4. Screw the fastener guide onto the tool until it engages.

8.14 Checking the tool following care and mainte-
nance

After carrying out care and maintenance on the tool,
check that all protective and safety devices are fitted and
that they function correctly.

NOTE

The use of lubricants other than Hilti spray could dam-

age rubber parts, especially the buffer.

Summary of Contents for DX 462

Page 1: ...ty rules 18 6 Before use 19 7 Operation 20 8 Care and maintenance 21 9 Troubleshooting 23 10 Disposal 27 11 Manufacturer s warranty DX tools 27 1 General information 1 1 Signal words and their meaning...

Page 2: ...he propellant charge is transferred to a piston the accelerated mass of which drives the fas tener into the base material As approximately 95 of the kinetic energy is absorbed by the piston the fasten...

Page 3: ...andard nail for efficient fastenings on steel With 12 mm washer for higher pull over loads X DAK Nail with stepped shank For fastening on high strength concrete or steel X CR Stainless steel nail for...

Page 4: ...This tool is designed with the latest available tech nology The tool and its ancillary equipment may present haz ards when used incorrectly by untrained personnel or not as directed 5 5 Make the workp...

Page 5: ...working with the tool if you feel unwell 5 9 Personal protective equipment The operator and other persons in the immediate vicin ity must always wear eye protection a hard hat and ear protection 6 Bef...

Page 6: ...the eyes Wear safety goggles and a hard hat users and bystanders X DNI nail concrete steel MD ET SL SD Length of nails for steel Penetration depth ET 22 5 mm nail point must protrude material thickne...

Page 7: ...section The ventilation slots must be unobstructed and kept clean at all times Do not permit foreign objects to enter the interior of the tool Use a slightly damp cloth to clean the outside of the too...

Page 8: ...he piston return unit lightly with Hilti spray 8 9 Clean inside the housing 1 Use the large round brush to clean inside the hous ing 2 Spray the inside of the housing lightly with Hilti spray 8 10 Cle...

Page 9: ...fully back See 9 1 Use longer fastener Use fastener with washer for wood applications Reduce power setting Power regulation Lower cartridge power level Change cartridge strip Clean the cartridge stri...

Page 10: ...r debris inside the piston return unit Damaged buffer Carbon build up Remove cartridge strip Unscrew piston return unit and push out the piston through the cartridge chamber using the pushrod provided...

Page 11: ...ridge Base material is spalling Nail bends Hard and or large aggregate in concrete Rebar close to surface of concrete Hard surface steel High strength concrete Hard and or large aggregate in concrete...

Page 12: ...Use co acting principle fastener guide Switch to more powerful system like DX 750 DX 600 N Try different power setting or different cartridge Try EDNK 20P8H or ENKK 20 S12 for fastening sheet metal Tr...

Page 13: ...onents and spare parts or other products of equiv alent quality may be used in the tool This warranty provides the free of charge repair or replacement of defective parts only over the entire lifes pa...

Page 14: ...circumstances of use most powerful cartridge power load in accordance with instructions for use with suitable nail or stud fired vertically downwards into a steel plate and in accordance with the mean...