Hilti DX 462 Operating Instructions Manual Download Page 7

21

en

쎱쎱

7.1

Loading the tool

1. Insert the fastener (head first) until the washer is held

in the tool.

2. Load the cartridge strip (narrow end first) by insert-

ing it into the bottom of the tool grip until flush. If the
strip has been partly used, pull it through until an
unused cartridge is in the chamber. (The last visible
number on the back of the cartridge strip indicates
which cartridge is next to be fired.)

쎱쎱

7.2

Adjusting the driving power

Start with the lowest cartridge power level and the tool
set at the lowest power setting.
1. Press the release button.
2. Turn the power regulation wheel to 1.
3. Drive a nail.
4. If the fastener doesn't penetrate deeply enough,

increase the power level and repeat steps 1 to 3.
Repeat until the desired depth of penetration is reached.
Use a more powerful cartridge if necessary.

쎱쎱

7.3

Fastening with the tool

1. Press the tool firmly against the work surface at right

angles.

2. Fire the tool by pulling the trigger.

WARNING

Never attempt to drive a fastener in an existing hole

except where recommended by Hilti, e.g. when using
the DX Kwik system.

Never attempt to redrive the same fastener.

Never exceed the maximum fastener driving rate.

쎱쎱

7.4

Reloading the tool

Ensure that no cartridge strip or fastener is loaded in the
tool. Remove the cartridge strip by pulling it upwards
out of the tool and remove the fastener from the fastener
guide.

8. Care and maintenance

8.1 Care of the tool

The outer casing of the tool is manufactured from impact-
resistant plastic. The grip comprises a synthetic rubber
section.
The ventilation slots must be unobstructed and kept
clean at all times. Do not permit foreign objects to enter
the interior of the tool. Use a slightly damp cloth to clean
the outside of the tool at regular intervals. Do not use a
spray or steam-cleaning system for cleaning.

8.2 Maintenance

Check all external parts of the tool for damage at regu-
lar intervals and check that all controls operate proper-
ly. Do not operate the tool when parts are damaged or
when the controls do not operate properly. If necessary,
have the tool repaired at a Hilti service centre.

CAUTION

The tool can get hot while oper-
ating.

You could burn your hands.

Do not disassemble the tool while
it is hot. Let the tool cool down.

Servicing the tool

The tool should be serviced if:
1. Cartridges misfire
2. Fastener driving power is inconsistent
3. If you notice that:

contact pressure increases,

trigger force increases,

power regulation is difficult to adjust (stiff),

the cartridge strip is difficult to remove.

CAUTION while cleaning the tool:

Never use grease for maintenance / lubrication of tool

parts. This may strongly affect the functionality of the
tool. Use only Hilti spray or such of equivalent quality.

Dirt from DX tool contains substances that could be

endangering your health.
– Do not breath in the dust from cleaning
– Keep dust away from food
– Wash your hands after cleaning the tool

쎱쎱

8.3

Disassemble the tool

1. Ensure that no cartridge strip or fastener is loaded in

the tool. Remove the cartridge strip by pulling it
upwards out of the tool and remove the fastener from
the fastener guide.

2. Press the release button at the side.
3. Unscrew the fastener guide.
4. Remove the buffer by bending it away from the fas-

tener guide.

5. Remove the piston.

Summary of Contents for DX 462

Page 1: ...ty rules 18 6 Before use 19 7 Operation 20 8 Care and maintenance 21 9 Troubleshooting 23 10 Disposal 27 11 Manufacturer s warranty DX tools 27 1 General information 1 1 Signal words and their meaning...

Page 2: ...he propellant charge is transferred to a piston the accelerated mass of which drives the fas tener into the base material As approximately 95 of the kinetic energy is absorbed by the piston the fasten...

Page 3: ...andard nail for efficient fastenings on steel With 12 mm washer for higher pull over loads X DAK Nail with stepped shank For fastening on high strength concrete or steel X CR Stainless steel nail for...

Page 4: ...This tool is designed with the latest available tech nology The tool and its ancillary equipment may present haz ards when used incorrectly by untrained personnel or not as directed 5 5 Make the workp...

Page 5: ...working with the tool if you feel unwell 5 9 Personal protective equipment The operator and other persons in the immediate vicin ity must always wear eye protection a hard hat and ear protection 6 Bef...

Page 6: ...the eyes Wear safety goggles and a hard hat users and bystanders X DNI nail concrete steel MD ET SL SD Length of nails for steel Penetration depth ET 22 5 mm nail point must protrude material thickne...

Page 7: ...section The ventilation slots must be unobstructed and kept clean at all times Do not permit foreign objects to enter the interior of the tool Use a slightly damp cloth to clean the outside of the too...

Page 8: ...he piston return unit lightly with Hilti spray 8 9 Clean inside the housing 1 Use the large round brush to clean inside the hous ing 2 Spray the inside of the housing lightly with Hilti spray 8 10 Cle...

Page 9: ...fully back See 9 1 Use longer fastener Use fastener with washer for wood applications Reduce power setting Power regulation Lower cartridge power level Change cartridge strip Clean the cartridge stri...

Page 10: ...r debris inside the piston return unit Damaged buffer Carbon build up Remove cartridge strip Unscrew piston return unit and push out the piston through the cartridge chamber using the pushrod provided...

Page 11: ...ridge Base material is spalling Nail bends Hard and or large aggregate in concrete Rebar close to surface of concrete Hard surface steel High strength concrete Hard and or large aggregate in concrete...

Page 12: ...Use co acting principle fastener guide Switch to more powerful system like DX 750 DX 600 N Try different power setting or different cartridge Try EDNK 20P8H or ENKK 20 S12 for fastening sheet metal Tr...

Page 13: ...onents and spare parts or other products of equiv alent quality may be used in the tool This warranty provides the free of charge repair or replacement of defective parts only over the entire lifes pa...

Page 14: ...circumstances of use most powerful cartridge power load in accordance with instructions for use with suitable nail or stud fired vertically downwards into a steel plate and in accordance with the mean...