background image

6

English

8

Care and maintenance

8.1

Care and maintenance work

1. Check the unit at regular intervals.

We recommend having an expert conduct an external inspection every 2 years and an internal

inspection every 5 years, as well as a strength test every 10 years

2. Dismantle the pump [1] and grease the O-ring [a] is and the sleeve [b].

3. Always carry out this maintenance after using the unit 50 times, however at least once a year!

To help ensure safe and reliable operation, use only genuine Hilti spare parts and consumables.

Spare parts, consumables and accessories approved by Hilti for use with the product can be

found at your local

Hilti Store

or online at:

www.hilti.group

.

9

Troubleshooting

If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by

yourself, please contact

Hilti

Service.

9.1

Troubleshooting table

Trouble or fault

Possible cause

Action to be taken

The water supply unit does

not build up any pressure

Pump is not screwed on tightly

Screw on the pump tightly.

O-ring on the pump is defective

Have the power tool repaired by

Hilti

Service.

Sleeve is defective

Have the power tool repaired by

Hilti

Service.

Liquid escapes from the

pump at the top

Valve disk is dirty or defective

Clean the valve disk or have the

unit repaired by

Hilti

Service.

Safety valve vents too early

Safety valve is defective

Have the tool repaired by

Hilti

Service.

Pressure gage indicates no

tank pressure

Pressure gage is defective

Have the power tool repaired by

Hilti

Service.

10

Disposal

Do not dispose of this product in household waste!

Most of the materials from which

Hilti

tools, appliances and devices are manufactured can be recycled.

The materials must be correctly separated before they can be recycled. In many countries, your old

tools, machines or appliances can be returned to

Hilti

for recycling. Ask

Hilti

Service or your Hilti sales

representative for further information.

Printed: 30.05.2018 | Doc-Nr: PUB / 5433246 / 000 / 00

Summary of Contents for DWP 10

Page 1: ...DWP 10 English Printed 30 05 2018 Doc Nr PUB 5433246 000 00 ...

Page 2: ...Printed 30 05 2018 Doc Nr PUB 5433246 000 00 ...

Page 3: ...illary equipment can present hazards if used incorrectly by untrained personnel or if used not in accordance with the intended use The type designation and serial number are printed on the rating plate Write down the serial number in the table below You will be required to state the product details when contacting Hilti Service or your local Hilti organization to inquire about the product Product ...

Page 4: ...g 3 2 Intended use The product described here is a water pressure tank for distributing coolants and flushing liquids on drilling rigs concrete saws or angle grinders Water is generally used for this purpose 3 3 Possible misuse This product is not suitable for Flammable liquids Hydrogen peroxide and similar oxygen emitting media Caustic substances certain disinfectants and impregnating agents acid...

Page 5: ...hilti com 4 Technical data The tank material consists of steel with a polyester coating Tare weight 5 2 kg Total content 13 ℓ Maximum filling quantity 10 ℓ Technical residual quantity 0 03 ℓ Maximum operating pressure 6 bar Maximum operating temperature 40 5 Preparations at the workplace 5 1 Assembling water supply unit 1 Check whether the tank pump and hose are undamaged before assembly 2 Connect...

Page 6: ...ad off on the scale 5 3 Preparing water supply unit 1 Screw the pump into the tank 1 2 Press the pump handle downward and turn it clockwise 2 The pump handle has been released 3 Generate a pressure of approx 2 bar in the tank 3 The maximum pressure should not exceed 6 bar red line on the pressure gage If the maximum pressure is exceeded the safety valve is actuated and releases the excess pressure...

Page 7: ...valve until the tank is completely depressurized 2 Close the ball valve and disconnect the plug in connection and plug in nipple 1 3 Lock the pump handle 4 Screw the pump out of the tank 5 Drain the remaining water from the tank 6 Wipe off the water supply unit with a damp cloth 7 Coil the hose around the tank and mount the plug in connection on the locating pin of the water supply unit 2 8 Keep t...

Page 8: ...ble cause Action to be taken The water supply unit does not build up any pressure Pump is not screwed on tightly Screw on the pump tightly O ring on the pump is defective Have the power tool repaired by Hilti Service Sleeve is defective Have the power tool repaired by Hilti Service Liquid escapes from the pump at the top Valve disk is dirty or defective Clean the valve disk or have the unit repair...

Page 9: ...DWP10 of the series 3585 meet the requirements of the Pressure Equipment Directive 2014 68 EU and bear the CE marking Please contact your local Hilti representative if you have questions about the warranty conditions Printed 30 05 2018 Doc Nr PUB 5433246 000 00 ...

Page 10: ...Printed 30 05 2018 Doc Nr PUB 5433246 000 00 ...

Page 11: ...Printed 30 05 2018 Doc Nr PUB 5433246 000 00 ...

Page 12: ...Hilti registered trademark of Hilti Corp Schaan 20180523 Printed 30 05 2018 Doc Nr PUB 5433246 000 00 ...