Malfunction
Possible cause
Action to be taken
The auto-feed unit cannot be
installed.
Square drive does not fit, or is not
turned to a position at which it can
slot into the adapter.
▶
Turn the auto-feed unit until the
square shaft and the square-
shaft socket are in alignment.
The flange on the carriage of the
drill stand or on the auto-feed unit
is dirty or worn.
▶
Clean the flange and check the
flange for excessive wear.
▶
Replace excessively worn
components.
The threaded bushing for the se-
curing screw is blocked.
▶
Clean the threaded bushing.
The hand wheel cannot be
rotated.
The carriage lock is engaged.
▶
Try to turn the auto-feed unit to
match up the flanges.
▶
Check the threaded bushings
and the threaded studs.
The carriage is obstructed.
▶
Make sure that the carriage is
free to move.
The water flow rate is too low. Strainer of the auto-feed unit is
clogged.
▶
Clean the strainer in the water
inlet.
Water valve of the auto-feed unit is
faulty or blocked.
▶
Connect the water supply
directly to the diamond core
drilling machine and check
whether the water valve on the
diamond core drilling machine
is working.
▶
Check whether the valve on
the auto-feed unit is blocked or
faulty.
▶
Check that the water supply is
installed correctly.
The auto-feed unit motor runs
but the carriage does not
move.
The auto-feed unit is installed in-
correctly.
▶
Check the mechanical connec-
tion between the auto-feed unit
and the carriage.
Cut Assist mode cannot be
activated.
Auto-feed unit has no AC supply.
▶
Check the electricity supply.
An emergency stop was triggered.
▶
Cancel the emergency stop by
pulling up the
EMERGENCY
STOP
switch. → page 18.
▶
If the problem persists, consult
Hilti
Service.
The drilling operation slows or
stops.
The diamond core bit is defective
(segments polished or destroyed).
▶
Sharpen the diamond core bit
or replace it.
The plug connector is faulty or the
cable is defective.
▶
Check the connection between
the auto-feed unit and the
diamond core drilling machine.
The diamond core bit is stuck.
▶
Disconnect the diamond core
drilling machine from the electric
supply.
▶
Release the diamond core bit.
Faulty or inadequate cooling.
▶
Check the water supply and
cooling circuit.
Stopped before reaching the target
depth due to transition into softer
material such as hollow brick, soil
or natural stone.
▶
Restart the drilling operation.
▶
Switch break-through detection
off.
The drilling system vibrates
severely during drilling.
The drill stand is inadequately fas-
tened.
▶
Check that the clamping spindle
nut is tightened securely.
Summary of Contents for DD AF-CA L
Page 1: ...DD AF CA L ע ב ר י ת 1 English 14 ...
Page 2: ...1 ...
Page 3: ...2 3 ...
Page 4: ......
Page 5: ...DD AF CA L ...
Page 6: ...he ה ו ר א ו ת ה פ ע ל ה מ ק ו ר י ו ת 1 en Original operating instructions 14 ...
Page 34: ...28 English 2289378 2289378 ...
Page 35: ......
Page 36: ...Hilti registered trademark of Hilti Corp Schaan Pos 1 20210304 2289378 2289378 ...