Switching off (switch with lock)
▶
Press the front part of the on/off switch down
◁
The on/off switch jumps into the off position and the motor stops.
8
Care and maintenance
WARNING
Danger of electric shock!
Carrying out care and maintenance while the supply cord is connected to the
power outlet presents a risk of serious injuries including burns.
▶
Always unplug the supply cord before carrying out all care and maintenance tasks.
Care
▶
Remove stubborn dirt.
▶
Clean the air vents carefully using a dry brush.
▶
Clean the housing at regular intervals, using a slightly damp cloth.
◁
Do not use cleaning agents containing silicone as these can attack the plastic parts.
Maintenance
▶
Check all visible parts and controls for signs of damage at regular intervals and make sure that they all
function correctly.
◁
Do not continue to operate the power tool if signs of damage are found or if parts malfunction.
▶
Use only genuine
accessories for repairs.
▶
After carrying out care and maintenance, check that all protective and safety devices are fitted and that
they function faultlessly.
9
Transport and storage
• Do not transport electric tools with accessory tools fitted.
• Always unplug the supply cord before storing an electric tool or appliance.
• Store tools and appliances in a dry place where they cannot be accessed by children or unauthorized
persons.
• Check electric tools or appliances for damage after long periods of transport or storage.
10
Troubleshooting
If the trouble you are experiencing isn’t listed in this table or you are unable to remedy the problem by
yourself, please contact
Hilti
Service.
Trouble or fault
Possible cause
Action to be taken
The power tool doesn’t start.
Interruption in the electric supply.
▶
Plug in another electric tool or
appliance and check whether it
works.
The supply cord or plug is defec-
tive.
▶
Have the supply cord and plug
checked by a trained electrical
specialist and replaced if
necessary.
The carbon brushes are worn.
▶
Have the power tool checked by
a trained electrical specialist and
the carbon brushes replaced if
necessary.
The restart interlock is active after
disconnection or an interruption in
the electric supply.
▶
First release the on/off switch
lockbutton and then switch on
again.
The tool does not achieve full
power.
The extension cord conductor
cross section (gauge) is inade-
quate.
▶
Use an extension cord with
an adequate conductor cross
section.
Malfunction in the ATC system.
▶
Have the product repaired by
Hilti
Service.
Printed: 29.03.2018 | Doc-Nr: PUB / 5164457 / 000 / 01
Summary of Contents for DCG 700-P
Page 2: ...1 Printed 29 03 2018 Doc Nr PUB 5164457 000 01 ...
Page 3: ...2 3 4 Printed 29 03 2018 Doc Nr PUB 5164457 000 01 ...
Page 4: ...5 6 Printed 29 03 2018 Doc Nr PUB 5164457 000 01 ...
Page 6: ...Printed 29 03 2018 Doc Nr PUB 5164457 000 01 ...
Page 56: ...50 Português 72022 72022 Printed 29 03 2018 Doc Nr PUB 5164457 000 01 ...
Page 57: ...Printed 29 03 2018 Doc Nr PUB 5164457 000 01 ...
Page 58: ...Printed 29 03 2018 Doc Nr PUB 5164457 000 01 ...
Page 59: ...Printed 29 03 2018 Doc Nr PUB 5164457 000 01 ...