Observe the information printed in the operating instructions concerning operation, care and maintenance.

The power tool is designed for professional use and may be operated, serviced and maintained only by trained,

authorized personnel. This personnel must be informed of any special hazards that may be encountered. The power

tool and its ancillary equipment may present hazards when used incorrectly by untrained personnel or when used not

as directed.

Modification of the power tool or tampering with its parts is not permissible.

2.2 Switches

On / off switch with switch-on interlock

2.3 Items supplied as standard include:

1 Power tool
1 Guard
1 Side handle
1 Clamping flange
1 Clamping nut
1 Wrench
1 Operating instructions
1 Cardboard box

2.4 Starting current limitation

The electronic starting current limiter reduces the starting current drawn by the power tool and thus prevents the

mains fuse blowing. It also allows the power tool to start smoothly, without a jolt.

2.5 Using extension cords

Use only extension cords of a type approved for the application and with conductors of adequate cross section. The

power tool may otherwise loose performance and the extension cord may overheat. Check the extension cord for

damage at regular intervals. Replace damaged extension cords.

Recommended minimum conductor cross section and max. cord lengths

Conductor cross section

14 AWG

12 AWG

10 AWG

Mains voltage 110-120 V

50 ft

100 ft

150 ft

Do not use extension cords with 16 AWG conductor cross section.

2.6 Using extension cords outdoors

When working outdoors, use only extension cords that are approved and correspondingly marked for this application.

2.7 Using a generator or transformer

This power tool may be powered by a generator or transformer when the following conditions are fulfilled: The unit

must provide a power output in watts of at least twice the value printed on the type identification plate on the power

tool. The operating voltage must remain 5% and -15% of the rated voltage at all times, frequency must be in

the 50 – 60 Hz range and never above 65 Hz, and the unit must be equipped with automatic voltage regulation and

starting boost.

Never operate other power tools or appliances from the generator or transformer at the same time. Switching other

power tools or appliances on and off may cause undervoltage and / or overvoltage peaks, resulting in damage to the

power tool.

2.8 Guard with cover plate

2

DANGER

When using abrasive cutting discs to cut or slit metals, the guard with cover plate must be fitted. When using

diamond cutting discs it is recommended that the guard with cover plate is fitted.

en

3

Printed: 02.04.2014 | Doc-Nr: PUB / 5169300 / 000 / 01

Summary of Contents for AG 700-14D

Page 1: ... 2075441 2075441 AG 700 14D Operating instructions en Mode d emploi fr Manual de instrucciones es Manual de instruções pt Printed 02 04 2014 Doc Nr PUB 5169300 000 01 ...

Page 2: ...ꙣ ꙤꙤ ꙥ ꙧ Ꙩ ꙮ Ꙭ ꙭ Ꙫ ꙩ ꙫ Ꙧ 1 This Product is Listed Ce produit est homologué Producto homologado por Este produto está registrado Printed 02 04 2014 Doc Nr PUB 5169300 000 01 ...

Page 3: ...2 3 4 Printed 02 04 2014 Doc Nr PUB 5169300 000 01 ...

Page 4: ... 7 5 PP PP 6 Printed 02 04 2014 Doc Nr PUB 5169300 000 01 ...

Page 5: ...s the designation the power tool always refers to the AG 700 14D angle grinder Parts operating controls and indicators 1 Drive spindle lockbutton Steadying rib On off switch Safety interlock Side handle Threaded bushing for grip Spindle Keyed locating lug Clamping lever Clamping flange Clamping nut Adjusting screw Guard Abrasive cutting disc abrasive grinding disc Wrench 1 General information 1 1 ...

Page 6: ...tion conversion or new construction The power tool may be operated only when connected to a power supply providing a voltage and frequency in compliance with the information given on its type identification plate Working with metals Cutting grinding Working with mineral materials Cutting slitting and grinding Use only discs abrasive grinding discs abrasive cutting discs etc that are approved for u...

Page 7: ...cord for damage at regular intervals Replace damaged extension cords Recommended minimum conductor cross section and max cord lengths Conductor cross section 14 AWG 12 AWG 10 AWG Mains voltage 110 120 V 50 ft 100 ft 150 ft Do not use extension cords with 16 AWG conductor cross section 2 6 Using extension cords outdoors When working outdoors use only extension cords that are approved and correspond...

Page 8: ...AF D AN D DG CW DC D Guard X X X X Guard with cover plate X X Side handle X X X X X X Clamping nut not for use with ac cessories with in tegrated thread X X X X X X Clamping flange not for use with accessories with integrated thread X X X X X X 4 Technical data Right of technical changes reserved Power tool AG 700 14D Rated power input 120 V Rated current input 15 A Rated frequency 60 Hz Rated spe...

Page 9: ...ropriate conditions will reduce personal injuries c Prevent unintentional starting Ensure the switch is in the off position before connecting to power source and or battery pack picking up or carrying the tool Carrying power tools with your finger on the switch or energising power tools that have the switch on invites accidents d Remove any adjusting key or wrench before turn ing the power tool on...

Page 10: ...s opera tions The dust mask or respirator must be capable of filtrating particles generated by your operation Pro longed exposure to high intensity noise may cause hearing loss i Keep bystanders a safe distance away from work area Anyone entering the work area must wear personal protective equipment Fragments of workpiece or of a broken accessory may fly away and cause injury beyond immediate area...

Page 11: ...ur body in line with and behind the rotating wheel When the wheel at the point of operation is moving away from your body the possible kickback may propel the spinning wheel and the power tool directly at you c When wheel is binding or when interrupting a cut for any reason switch off the power tool and hold the power tool motionless until the wheel comes to a complete stop Never attempt to remove...

Page 12: ...aled electric cables or gas and water pipes are present External metal parts of the power tool may become live for example when an electric cable is damaged accidentally This presents a serious risk of electric shock b Check the power tool s supply cord at regular intervals and have it replaced by a qualified spe cialist if found to be damaged If the power tool s supply cord is damaged it must be ...

Page 13: ...5 To remove the guard from the power tool follow the instructions for fitting the guard but carry out the steps in the reverse order 6 2 2 Adjusting the guard or guard with cover plate 4 1 Release the clamping lever 2 Rotate the guard to the desired position 3 Close the clamping lever 6 3 Fitting and removing the disc 5 6 CAUTION Wear gloves when fitting or removing parts when making adjustments o...

Page 14: ...N The insert tool may get hot during use Wear protective gloves when changing insert tools CAUTION In accordance with the applications for which it is de signed the power tool produces a high torque Always use the side handle and hold the power tool with both hands The user must be prepared for sudden sticking and stalling of the insert tool CAUTION Working on the material may cause it to splinter...

Page 15: ... the elec trical safety of the tool Always keep the grip surfaces of the tool free from oil and grease Do not use cleaning agents which contain silicone NOTE Frequent work on conductive materials e g metal car bon fiber may make shorter maintenance intervals nec essary Take your individual work place risk assessment into account 8 2 Maintenance WARNING Do not operate the power tool if parts are da...

Page 16: ... may be used in the tool This warranty provides the free of charge repair or re placement of defective parts only over the entire lifespan of the tool Parts requiring repair or replacement as a result of normal wear and tear are not covered by this warranty Additional claims are excluded unless stringent na tional rules prohibit such exclusion In particular Hilti is not obligated for direct indire...

Page 17: ... Tel 423 2342111 Fax 423 2342965 www hilti com Hilti registered trademark of Hilti Corp Schaan W 4331 0214 00 Pos 3 1 Printed in China 2014 Right of technical and programme changes reserved S E O 2075441 A3 Printed 02 04 2014 Doc Nr PUB 5169300 000 01 ...

Reviews: