Hardware Installation and Uninstalling
46/71
netSCOPE Data Acquisition Cards for Real-Time Ethernet | Installation, Operation and Hardware Description
DOC131006UM01EN | Revision 1 | English | 2013-11 | Released | Public
© Hilscher, 2013
7.4
Uninstalling netSCOPE Data Acquisition Cards
1. Take safety precautions.
Lethal Electrical Shock caused by parts with more than 50V!
Disconnect the power plug of the PC or of the connecting device.
Make sure, that the power supply is off at the PC or at the connecting
device.
Electrostatically sensitive Devices
To prevent damage to the PC and the netSCOPE card, make sure, that
the netSCOPE card is grounded via the endplate and the PC and make
sure, that you are discharged when you install/uninstall the netSCOPE
card.
2. Remove the Ethernet connecting cables.
Remove the Ethernet connecting cables between the netSCOPE data
aquistion card and the Master or the Device.
3. Open
cabinet.
Open the cabinet of the PC or of the connecting device.
4. Uninstall netSCOPE data aquistion card.
PCI, PCI Express or Low Profile PCI Express:
Loosen the netSCOPE data aquistion card.
Remove the netSCOPE data aquistion card from the
PCI
slot or from
the
PCI express
slot.
Compact PCI:
Unscrew the netSCOPE data aquistion card.
First press the grey button at the ejection lever.
Then press the ejection lever downwards.
Remove the netSCOPE data aquistion card from the compact PCI slot.
Possibly reinsert a blank plate.
Mini PCI Express:
5. Uninstall the Ethernet (AIFX-RE) assembly interface. (Only NSCP-
C100-RE\90E)
Remove the AIFX-RE assembly interface from the PC housing panel.
Disconnect the cable from the basic card NSCP-C100-RE\90E, cable
connector Ethernet X4.