Figure 6-17 Elevator Control
2. Check to enable elevator control function.
3. Select an Elevator No., and select an elevator controller type for the elevator.
4. Set the Negative Floor.
5. Select the Interface Type as RS-485 or Network Interface. And enable the
elevator control.
-
If you select RS-485, make sure you have connected the door station to the
elevator controller with RS-485 wire.
-
If you select Network interface, enter the elevator controller's IP address,
port No., user name, and password.
6. Click Save to enable the settings.
Note
• Up to 4 elevator controllers can be connected to one door station.
• Up to 10 negative floors can be added.
• Make sure the interface types of elevator controllers, which are connected
to the same door station are consistent.
Video Intercom D Series Door Station User Manual