User Manual of iDS-TP40-16B Traffic Incident Detection Server
11
Preparation
Check the whether the packaging is damaged.
Pick a proper installation location that is dust-free and well-ventilated.
Avoid heat/noise generating environment; be close to grounded power socket.
Keep the device in dry environment. Rain drops, moisture and liquids will corrode the circuit.
The device is a precision equipment and should be handled with anti-static measures during
installation and operation.
The server should not share a power socket with other devices; extension cord is not
recommended; connect the server to a UPS if possible.
The device is a Class A product and may cause radioactive interference. In this case, necessary
measures should be taken.
Installing Power Module
The device comes with two standard 100 to 240 V power modules. To install a power modules:
1.
Align the module with the rail.
2.
Clip the rear of module into the slot and push the module along the rail.
3.
Push the module further until its front is leveled with the rear panel of the server to make sure
the module is successfully mounted.
Removing Power Module
To remove a power module:
1.
Press the blue paddle to the left while pulling the module out.
2.
Pull the module out until it is completely removed from the server.
Installing on Chassis
The chassis should match the size of guide rails. The distance between the front and back columns
of the chassis should be within the range of 660 mm to 850 mm.
Installing Inner Rail
1.
Ensure that the second half of left and right inner rails is set into place. The first half of the
inner rails has already been preinstalled on the device.
2.
Clip the second part of the inner rail into the hook of both sides of the device and make sure
the screw holes are aligned to those on the inner rails.