User Manual of DS-TCG227-A Series Entrance/Exit Capture Unit
49
configured according to the actual conditions.
RS-485
1)
Select the
Picture Mode
.
Scene Picture
and
Scene P Close-up
Picture
are selectable.
2)
Select the
Scene Mode
.
Entrance and Exit
,
Toll Station
, and
Entrance
and Exit of Underground Parking Lot
are selectable.
3)
Enter the
Linked Lane No.
ranging from 1 to 99. The lane No. will be
overlaid on the captured picture.
4)
Enter the
RS-485 Linked Camera No.
ranging from 1 to 16. The No.
refers to the RS-485 serial port connected channel No. of the vehicle
detector.
3.
Click
Draw LPR Area
to enter the License Plate Recognition System
Configuration page. A default LPR area is displayed on the screen.
Figure 6-36
Draw LPR Area
1)
Check the lines to be displayed.
2)
(Optional) Click
Redraw LPR Area
. Refer to Chapter 2.7.2 Adjust Image
for reference
3)
Click
OK
to save the settings.
4.
(Optional) Click
Get Recommended Value
to get the default value.
5.
Click
Save
to save the settings.
6.7
Configure Capture Parameters
6.7.1
Configure License Plate Recognition Parameters
Purpose
:
You can configure the license plate type for recognition.