Panic Alarm Station
User Manual
52
Device ID
The device ID number can only be set as a number and no more than 6 digits. The ID is the
unique identification of the device, which facilitates the interaction between the panic alarm
center station and front-end device.
6. Click Save.
Alarm Communication
Steps
1. Click Network → Alarm Communication.
2. Enable Wired Network and set parameters.
Notify Surveillance Center
Each network card only supports one upload center, which is Wired Network1 by default.
Server Type
Address type of central server. You can select as IPv4 or Domain.
IP/Domain
Enter the IP address or domain name of the server according to the set server type.
Port
The central port number. The HIK protocol is 7200 by default. The NAL2300 protocol should be
set as 4001.
Protocol
The default protocol is HIK Protocol.
User Name
It supports numbers and letters. The HIK protocol can set the length range to 6~9 digits. The
NAL2300 protocol can set the length range to 6 digits.
3. Click Save.
Configure the video and audio parameters of the channels.
Video
Click Video/Audio → Video to set video parameters, which will take effect after saving.
Stream Type
You can select Main Stream or Sub-Stream to see the live view. The default type is main stream.
Main stream is used for high-definition storage and preview.
Sub-stream is used for standard definition storage and preview when the network bandwidth
is insufficient.
Video Type
You can select Mixed Flow or Video Flow. The default is mixed flow, that is, the video contains
sound and pictures. If you do not need sound, you can select video flow.