Summary of Contents for DS-PEA102R

Page 1: ...Panic Alarm Station User Manual...

Page 2: ...N OR LOSS OF DATA CORRUPTION OF SYSTEMS OR LOSS OF DOCUMENTATION WHETHER BASED ON BREACH OF CONTRACT TORT INCLUDING NEGLIGENCE PRODUCT LIABILITY OR OTHERWISE IN CONNECTION WITH THE USE OF THE PRODUCT...

Page 3: ...outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Conditions This device complies with part 15 of the FCC...

Page 4: ...Manual iii the battery to your supplier or to a designated collection point For more information see www recyclethis info Industry Canada ICES 003 Compliance This device meets the CAN ICES 3 A NMB 3...

Page 5: ...ating or fire hazards caused by overload Make sure the plug is properly connected to the power socket If smoke odor or noise arises from the device immediately turn off the power unplug the power cabl...

Page 6: ...nt The average lifespan varies so periodic checking is recommended Contact your dealer for details Improper use or replacement of the battery may result in explosion hazard Replace with the same or eq...

Page 7: ...1 3 2 3 Set NAT 21 3 2 4 Set SIP 23 3 2 5 Set Hik Connect 23 3 2 6 Access the Platform 24 3 2 7 Set Alarm Center 25 Alarm Settings 27 3 3 1 Set Zone 27 3 3 2 Set Relay 29 3 3 3 Set Call Waiting 30 3 3...

Page 8: ...ck Zone Status 47 3 7 2 Check Relay Status 47 Other Settings 47 3 8 1 Set Auxiliary Output 47 Chapter 4 Web Client Settings 48 Live View 48 Configuration 48 4 2 1 System 48 4 2 2 Network 49 4 2 3 Vide...

Page 9: ...in school hospital metro scenic area prison etc Key Features Network adaptive and video and audio adaptive Built in omnidirectional microphone Supports two way audio communication and configuration S...

Page 10: ...how to activate a device and modify its IP address For batch activation and IP addresses modification refer to User Manual of SADP for details Steps 1 Run the SADP software and search the online devic...

Page 11: ...ce status from the online device list and select an inactive device 5 Click Activate 6 Create and confirm the admin password of the device STRONG PASSWORD RECOMMENDED We highly recommend you create a...

Page 12: ...he device You need to add the device to the client software before configure it See Add Device via Client Software Get the client software from the technical support and install the software according...

Page 13: ...or the client software The SADP software is taken as an example for explanation Steps 1 Run the SADP software check the activated device and edit the IP Address Subnet Mask Gateway and other parameter...

Page 14: ...set the network address IPv4 Address Subnet Mask IPv4 Gateway Address IPv4 4 Set the MTU Byte Device Port HTTP port and RTSP port for the device MTU Byte Maximum transmission unit which refers to the...

Page 15: ...CP is enabled the DNS cannot be set Enable the UPnP function and you don t need to configure the port mapping for each port and the device is connected to the Wide Area Network via the router Steps Un...

Page 16: ...rily edit the default port number If there is a port conflict and you need to edit the port number please modify the port number as follows HTTP Port By default the value of the HTTP port No is 80 Ser...

Page 17: ...IP Settings Page Private Protocol SIP Protocol 2 Check Enable box to enbale the Sip server 3 Enter the Sip server parameters The server port No ranges from 1024 to 65535 The device ID ranges from 0 to...

Page 18: ...r address Note The default server address is litedev hik connect com 4 Select Network Mode 5 Enter a verification code and click Generate QR code There will be a QR code displaying on the page 6 Click...

Page 19: ...he port number of the platform Panel ID Panel ID is the unique identification of the device Communication Network Select the network mode for communication with platform Registration Status Display th...

Page 20: ...ter and the default is Net Center 1 Server Mode The address type of the upload center server You can set Server Type as IP4 IP6 or Domain Name IP Address Server Domain Name Enter the server IP address...

Page 21: ...ne has a default zone type default audio file and the default zone will automatically upload an alarm recovery report These three parameters Zone Type Audio File and Upload Alarm Recovery Report do no...

Page 22: ...riggered an alarm is generated immediately without delay Fire Zone The fire zone must be set to a 24 hour alarm zone When the fire zone is triggered start the external siren sounder 24 hour Non voiced...

Page 23: ...triggered the selected alarm output is on Channel After the zone is triggered the selected video channel is linked 6 Optional Click Copy to copy the zone parameter configuration to other zones 7 Click...

Page 24: ...duration and waiting time Steps 1 Click to enter the Remote Configuration page go to Output Settings Waiting Call Waiting Settings Page 2 Set the call waiting parameters Calling Duration The playback...

Page 25: ...eriod Modify the time period Click and select the added time period drag to modify the time period position click and select the added time period then moves the cursor to both ends of the time period...

Page 26: ...Management Relay Relay Check the relays that need to be turned on off Click Enable Locked to change the relay switch status Click Refresh you can refresh the relay switch status Configure the audio i...

Page 27: ...nd volume spkOut is the device s own audio input output 3 Click Save Upload the custom audio files to SD card and delete the audio file in the SD card Before You Start Insert the SD card into the devi...

Page 28: ...t the beginning and end The length of the file name should be not more than 31 and the file name cannot contain symbols Each audio file size up to 2MB and up to 16 audio files are uploaded An audio fi...

Page 29: ...age capacity to configure the video and audio parameters Stream Type The stream type of camera can be set as Main Stream or Sub Stream By default it is Main Stream The main stream is used for HD stora...

Page 30: ...is the Main Stream the audio encoding type can be set as G711_U AAC or PCM And the audio encoding type of the sub stream is the same as the audio encoding type set in the main stream Video Encoding T...

Page 31: ...l be updated Editing the display format Date Format Select the display format of the date in the Date Format Drop Down box Time Format Select Time Format as 24 hour or 12 hour OSD Format There are fou...

Page 32: ...area of the check box in the Text Overlay List and enter display content in the text box Check the text and click Save to display the custom information You can drag the content to modify the location...

Page 33: ...rop down box And click Save to save the settings System Settings Click to enter the Remote Configuration page go to Device Information Time Time You can set the time zone NTP DST on the Time page You...

Page 34: ...configuration for remote debugging Click to enter the Remote Configuration page go to System Security Secuirty Check Enable SSH to enable SSH service and click Save By default the SSH service is not...

Page 35: ...assword attempts and lock duration Max Password Attempts The maximum times that the user attempts to enter the password By default it is 7 the available value is 3 to 10 Lock Time The lock duration of...

Page 36: ...nd confirm it 3 Click Save User Search and view the alarm logs exception logs operation logs and event logs Click to enter the Remote Configuration page go to System Log Query You can set the search c...

Page 37: ...Panic Alarm Station User Manual 43 Log Query You can click Backup and download the search result Click to enter the Remote Configuration page go to System Security Audit Log Security Audit Log...

Page 38: ...tore default settings restore all settings and import export configuration file Reboot Restart the device Restore Default Settings Restore the default settings that is except the IP address and user i...

Page 39: ...ord for the exported file The password is used for importing verification Remote Upgrade Upgrade the device remotely via the client software Click and select the upgrading file And click Upgrade to up...

Page 40: ...the week The device performs a check at the set time on this day of the week Manual check Click Verity to start the check and the check results are displayed in the list Table 3 1 Description of Chec...

Page 41: ...us Relay you can view the relay status Other Settings Enable the auxiliary power output to use the 12 V auxiliary power Steps 1 Click to enter the Remote Configuration page go to Other Auxiliary Power...

Page 42: ...ion Click System System Settings Basic Information You can change device name in this page And you can see device No Model Serial NO version etc System Settings Time Settings Click System System Setti...

Page 43: ...en there is a port conflict and you need to change the port number please change the following information accordingly HTTP S HTTP The default HTTP port is 80 To change the port you need to add the ch...

Page 44: ...can communicate with each other Click Network Device Access SIP Private Protocol Steps 1 Enable SIP Enrollment Status Display the device enrollment status If the device has been enrolled to the SIP se...

Page 45: ...he verification code 3 Set Server Address You can select default or custom When Custom is checked you need to set the server address manually You can contact the technical support to get the address 4...

Page 46: ...r The HIK protocol is 7200 by default The NAL2300 protocol should be set as 4001 Protocol The default protocol is HIK Protocol User Name It supports numbers and letters The HIK protocol can set the le...

Page 47: ...he I frame interval is the smaller the code stream fluctuation is but the image quality is relatively poor On the contrary the larger the code stream fluctuation is the higher the image quality is It...

Page 48: ...nformation After saving the displayed information will be updated to a new position Change Display Format Date Format You can select the date display format in the date format drop down box Time Forma...

Page 49: ...Content Select whether to display the name date or week according to your need After selecting the corresponding information will be displayed on the image Channel Name You can change the channel nam...

Page 50: ...t there is no alarm sound Disabled No event will trigger an alarm Audio File Select the zone audio file Mute can be selected Upload Restored Alarm After enabling when the alarm is recovered the report...

Page 51: ...extension time of the prompt tone based on the maximum ringing time is call extension time The range is 10 to 60 seconds 3 Click Save Voice Prompt Steps 1 Click Two way Audio Settings Voice Prompt 2...

Page 52: ...select the file address in the pop up window and import Note Audio file is wav or mp3 format the file name can be composed of English characters numbers and Chinese characters and does not contain sp...

Page 53: ...ort configuration file which includes device parameters Restore to Default Settings Click Restore device parameters except for IP address will restore to default settings Restore to Factory Settings C...

Page 54: ...is unable to detect audio output status IP Address Filter Steps 1 Click Maintenance and Security Security IP Address Filter 2 Enable filter click Add to add IP address to the list 3 Click to change I...

Page 55: ...to 10 Locking Duration The default setting is 600 seconds and the setting range is 10 to 3600 3 Click Save Note If you enter the wrong password more than the set number of times the IP address of the...

Page 56: ...Panic Alarm Station User Manual 62 Chapter 5 Communication Matrix and Device Command Scan the QR code to get the communication matrix and device command...

Page 57: ...Panic Alarm Station User Manual 63 UD24372B...