2.5.2 Alarm Output Connection
The alarm output interfaces A1 and B1 of the device is opened normally if no alarm occurs.
When an alarm output is triggered, the corresponding A1 and B1 interfaces will be
connected. Thus, the active alarm device is required for the system.
DC
Figure 2-24
Alarm Output Connection
2.6 Sensor-in Wiring
Step 1
Connect the delivered extension cable to I/O interface.
Step 2
Connect the vehicle braking, reversing, left-turn, and right-turn signals to sensor-in
interface.
2.7 Power Cord Wiring
2.7.1 Shutdown Delay
Purpose:
The device starts up when the vehicle ignites and shuts down after the vehicle is off. The
vehicle ignition startup and shutdown are realized by the vehicle positive pole ignition switch
(providing high level signal when the switch closes). The wire connection of the device varies
with the vehicle ignition models.
Ignition switch is connected to the positive pole of +12/24 VDC of vehicle batteries. Make
sure that the connection is correct, and then perform the following steps:
Step 1
Connect the "DC IN +" of the device to the positive pole of vehicle batteries, jumping
over the switch of normal vehicle power.
Step 2
Connect the "DC IN -" of the device to the negative pole of vehicle batteries.
Step 3
Connect the "ACC" of the device to the vehicle ignition switch.
Summary of Contents for DS-MP7516 Series
Page 1: ...Mobile Network Video Recorder User Manual 0 Mobile DVR User Manual UD07123N...
Page 23: ...Mobile Network Video Recorder User Manual 22 Figure 2 26 Timing On Off...
Page 77: ...Mobile Network Video Recorder User Manual 76 Step 3 Click OK...
Page 87: ...Mobile Network Video Recorder User Manual 86 UD08343N...