Figure 7-24
Access Control and Elevator Configuration
Access Control
1.
Select the door No.
2.
Set the door-unlocked duration.
3.
(Optional) Enable
Delay Door Alarm
.
4.
Click
Save
to enable the settings.
The door-unlocked duration ranges from 1s to 225s.
If you check
Delayed Door Alarm
, an alarm will be triggered automatically if the door
is not locked in the configured duration.
Enabling
Card Encrypt
, the door station can recognize the encrypted information of
the card when you swiping the card on the door station.
Elevator Control
Before you start
Make sure your door station is in the mode of main door station. Only the main door
station support elevator control function.
Make sure your door station have been connected to the elevator controller via
RS-485 wire if you want to use RS-485 interface.
Connection between the door station and the elevator controller supports 2 types:
RS-485 or Network interface.
Step:
1.
Select an elevator No., and select an elevator controller type for the elevator.