Video Intercom Door Station
·
User Manual
29
Figure 7-22
ID Configuration (Villa Door Station and Doorphone)
2.
Select the device type from the drop-down list, and set the corresponding
information.
3.
Click the
Save
button to enable the device number configuration.
For main door station (D series or V series), the serial No. is 0.
For sub door station (D series or V series), the serial No. is higher than 0. Serial No.
ranges from 1 to 99.
For each villa or building, at least one main door station (D series or V series)
should be configured, and sub door stations (D series or V series) can be
customized.
For one main door station (D series or V series), at most 8 sub door stations can
be customized.
Select doorphone as device type, and the serial No. is not necessary to configure.
Please utilize the doorphone along with the main door station (V Series or D
Series).
V series door station cannot be used as outer door station.
Time Parameters
1.
Click the
Time Parameters
button to enter time parameters settings interface.
2.
Configure the maximum ring duration, maximum live view time, and call forwarding
time.
3.
Click the
Save
button.
Figure 7-23
Time Parameters
For door station, maximum speaking time and maximum message time should be
configured. Maximum speaking time varies from 90s to 120s, and maximum
message time varies from 30s to 60s.
Access Control and Elevator
Click
Access Control and Elevator
to enter corresponding configuration page.