No.
Device Mode
UART No.
Function
Binary Value
Prohibit Entrance
and Controlled
Exit
Prohibit Entrance
and Free Exit
DIP B
1 to 3
UART 5
ON: UART 5 is RS-
232E Interface
/
4 to 6
ON: UART 5 is RS-
485E Interface
/
7
/
Reserved
/
8
/
Default is OFF. You
can dial to ON for
initial operation
/
DIP C
1 to 3
UART 6
ON: UART 6 is RS-
232F Interface
/
4 to 6
ON: UART 6 is RS-
485F Interface
/
7
/
Reserved
/
8
/
Reserved
/
DIP D
1 to 3
UART 1
ON: UART 1 is RS-
232A Interface
/
4 to 6
ON: UART 1 is RS-
485A Interface
/
7
/
Reserved
/
8
/
Reserved
/
DIP E
1 to 3
UART 3
ON: UART 3 is RS-
232C Interface
/
4 to 6
ON: UART 3 is RS-
485C Interface
/
7
/
Reserved
/
8
/
Reserved
/