DS-K1100 Series Card Reader 

 
 
 
 

Installation  Manual 

UD.6L0206A1003A01

 

Summary of Contents for DS-K1101C

Page 1: ...DS K1100 Series Card Reader Installation Manual UD 6L0206A1003A01...

Page 2: ...d DS K1102C CPU card reader without keypad DS K1102CK CPU card reader with a keypad DS K1103 Series DS K1103M MIFARE card reader without keypad DS K1103MK MIFARE card reader with a keypad DS K1103C CP...

Page 3: ...is installed outside or in environment easy to permeable it is advisable to install a waterproof shield If you need to install several card readers the distance among them must over 30cm To reduce the...

Page 4: ...s shown below Figure 2 1 DS K1101MK DS K1101CK Figure 2 2 DS K1101M DS K1101C The front view of DS K1102 series card reader is shown below Figure 2 3 DS K1102MK DS K1102CK Figure 2 4 DS K1102M DS K110...

Page 5: ...4 Figure 2 5 DS K1103MK DS K1103CK Figure 2 6 DS K1103M DS K1103C 2 2 Rear View The rear view of card reader is shown below 1 2 3 4 5 Figure 2 7 Rear View of DS K1101 Series...

Page 6: ...5 1 3 4 5 Figure 2 8 Rear View of DS K1102 Series 3 5 1 4 Figure 2 9 Rear View of DS K1103 Series...

Page 7: ...me 1 Cable Interface of RS 485 Power LED Control etc 2 Buzzer 3 Tamper proof Module 4 DIP Switch 5 PSAM Card Slot available for CPU card reader 2 3 Side View The side view of card reader is shown belo...

Page 8: ...of DS K1102 Series Figure 2 12 Side View of DS K1103 Series Chapter 3 Installation 3 1 Installing PSAM Card PSAM card slot is only available for CPU card reader Insert the PSAM card into the slot acc...

Page 9: ...le is shown below The No of DIP switch from left to right is 1 8 Figure 3 2 DIP Switch Module Table 3 1 Description of DIP Switch Icon Description Represent 1 in binary mode Represent 0 in binary mode...

Page 10: ...egand protocol of 26 bit 0 Wiegand protocol of 34 bit 8 Matched Resistance available for RS 485 protocol 1 Enable 0 Disable 3 3 Definition of Cable The description of 10 cables is shown below Table 3...

Page 11: ...ntroller and card reader thus to establish the communication between them Steps for RS 485 communication mode 1 Set the DIP switch of No 6 as 0 2 Set the DIP switch of No 1 5 for RS 485 address and re...

Page 12: ...mmunication Mode Steps for Wiegand communication mode 1 Set the DIP switch of No 6 as 1 2 Set the DIP switch of No 5 and 7 for reading card mode and Wiegand protocol For details please refer to 3 2 In...

Page 13: ...White Purple Orange Brown Controller Card Reader Figure 3 5 Wiring for Wiegand Communication Mode 3 5 Installing Card Reader Before you start Set the DIP switch For details refer to 3 2 Introduction f...

Page 14: ...r Chapter 4 Sound Prompt and Indicator After the card reader is powered on LED status indicator will turn blue and blink for 1 time Then it will turn red and blink for 3 times At last the buzzer will...

Page 15: ...roof Slowly continuous beeps The card reader is unencrypted Table 4 2 Description of LED Indicator LED Indicator Status Description Blue and blinking Card reader is working normally Solid blue The ope...