Color 

Description 

Orange 

Red LED Control (available for Wiegand Protocol) 

Red 

PWR (DC +12V) 

3.4

 

Wiring Cables 

Purpose: 

Wire  the  cables  between  controller  and  card  reader,  thus  to 

establish the communication between them. 

Steps for RS-485 communication mode: 

1.

 

Set the DIP switch of No. 6 as 0. 

2.

 

Set  the  DIP  switch  of  No.  1  ~  5  for  RS-485  address  and 
reading  card  mode.  For  details,  please  refer  to 

3.2 

Introduction for DIP Switch

3.

 

Wire  the  cable  between  controller  and  card  reader  as 
shown below. 

Summary of Contents for DS-K1101C

Page 1: ...DS K1100 Series Card Reader Installation Manual UD 6L0206A1003A01...

Page 2: ...d DS K1102C CPU card reader without keypad DS K1102CK CPU card reader with a keypad DS K1103 Series DS K1103M MIFARE card reader without keypad DS K1103MK MIFARE card reader with a keypad DS K1103C CP...

Page 3: ...is installed outside or in environment easy to permeable it is advisable to install a waterproof shield If you need to install several card readers the distance among them must over 30cm To reduce the...

Page 4: ...s shown below Figure 2 1 DS K1101MK DS K1101CK Figure 2 2 DS K1101M DS K1101C The front view of DS K1102 series card reader is shown below Figure 2 3 DS K1102MK DS K1102CK Figure 2 4 DS K1102M DS K110...

Page 5: ...4 Figure 2 5 DS K1103MK DS K1103CK Figure 2 6 DS K1103M DS K1103C 2 2 Rear View The rear view of card reader is shown below 1 2 3 4 5 Figure 2 7 Rear View of DS K1101 Series...

Page 6: ...5 1 3 4 5 Figure 2 8 Rear View of DS K1102 Series 3 5 1 4 Figure 2 9 Rear View of DS K1103 Series...

Page 7: ...me 1 Cable Interface of RS 485 Power LED Control etc 2 Buzzer 3 Tamper proof Module 4 DIP Switch 5 PSAM Card Slot available for CPU card reader 2 3 Side View The side view of card reader is shown belo...

Page 8: ...of DS K1102 Series Figure 2 12 Side View of DS K1103 Series Chapter 3 Installation 3 1 Installing PSAM Card PSAM card slot is only available for CPU card reader Insert the PSAM card into the slot acc...

Page 9: ...le is shown below The No of DIP switch from left to right is 1 8 Figure 3 2 DIP Switch Module Table 3 1 Description of DIP Switch Icon Description Represent 1 in binary mode Represent 0 in binary mode...

Page 10: ...egand protocol of 26 bit 0 Wiegand protocol of 34 bit 8 Matched Resistance available for RS 485 protocol 1 Enable 0 Disable 3 3 Definition of Cable The description of 10 cables is shown below Table 3...

Page 11: ...ntroller and card reader thus to establish the communication between them Steps for RS 485 communication mode 1 Set the DIP switch of No 6 as 0 2 Set the DIP switch of No 1 5 for RS 485 address and re...

Page 12: ...mmunication Mode Steps for Wiegand communication mode 1 Set the DIP switch of No 6 as 1 2 Set the DIP switch of No 5 and 7 for reading card mode and Wiegand protocol For details please refer to 3 2 In...

Page 13: ...White Purple Orange Brown Controller Card Reader Figure 3 5 Wiring for Wiegand Communication Mode 3 5 Installing Card Reader Before you start Set the DIP switch For details refer to 3 2 Introduction f...

Page 14: ...r Chapter 4 Sound Prompt and Indicator After the card reader is powered on LED status indicator will turn blue and blink for 1 time Then it will turn red and blink for 3 times At last the buzzer will...

Page 15: ...roof Slowly continuous beeps The card reader is unencrypted Table 4 2 Description of LED Indicator LED Indicator Status Description Blue and blinking Card reader is working normally Solid blue The ope...

Reviews: