![HIKVISION DS-7600NXI-K1 Series User Manual Download Page 70](http://html.mh-extra.com/html/hikvision/ds-7600nxi-k1-series/ds-7600nxi-k1-series_user-manual_2132957070.webp)
Network Video Recorder User Manual
58
Alarm Input
Set linkage actions for an external sensor alarm.
Steps
1. Go to Configuration → Event → Normal Event → Alarm Input.
Figure 6-19 Alarm Input
Note
Local alarm input: Local alarm input is triggered by the external device that connected to the
video recorder's terminal block.
2. Click
of a desired alarm input.
Figure 6-20 Edit Alarm Input
3. Customize Alarm Name.
4. Set alarm type as N.O (normally open) or N.C (normally closed).
5. Set Settings as Input to enable the function.
6. Set the arming schedule. Refer to Configure Arming Schedule for details.
7. Set the linkage actions. Refer to Configure Alarm Linkage Action for details.
8. Click Apply.
Alarm Output
Trigger an alarm output when an alarm is triggered.
Steps
1. Go to Configuration → Event → Normal Event → Alarm Output.
Figure 6-21 Alarm Output
2. Click
of a desired alarm output.
3. Customize Alarm Name.
Summary of Contents for DS-7600NXI-K1 Series