User Manual of Digital Video Recorder
106
8.2
Setting Sensor Alarms
Purpose:
You can set handling method of an external sensor alarm.
Note:
DS-7600HI-ST series HDVR only supports the sensor alarm of the IPC that connected to it.
Steps:
1.
Enter Alarm Settings interface and select an alarm input.
Menu> Configuration> Alarm
Figure 8. 7
Alarm Status Interface
2.
Select
Alarm Input
tab to enter Alarm Input Settings interface, edit the name for the alarm input and set
the handling method of the selected alarm input.
Check
checkbox to enable the alarm input and click
to configure the alarm settings..
Figure 8. 8
Alarm Input Settings Interface
3.
Select
Trigger Channel
tab and select one or more channels which will start to record or become
full-screen monitoring when an external alarm is input. Click
to save the settings.
4.
Select
Arming Schedule
tab to set the channel’s arming schedule.
Choose one day of a week and up to eight time periods can be set within each day. Set up arming schedule
of other days of a week. You can also use
to copy an arming schedule to other days. Click
to save the settings.
Note:
Time periods shall not be repeated or overlapped.
Lo-Call 1890 866 900 www.cctvireland.ie