After you enable/disable the soft address, the speed dome will reboot automatically to
activate the settings.
To Set the Broadcast Address of the Speed Dome
When the
BROADCAST ADDRESS
is set to
ON
, the control device with address 0 is capable of
controlling all domes connected to it.
Soft Baud Rate Settings
If the
SOFT BAUD ACTIVE
is set as
ON
, the soft baud rate is the valid baud rate for the speed dome,
with 2400, 4800, 9600 and 19200 selectable.
If the
SOFT BAUD ACTIVE
is set as
OFF
, the baud rate should be set by the DIP switch.
Note:
After you enable/disable the soft baud rate, the speed dome will reboot automatically to
activate the settings.
PELCO Checksum
The PELCO CHECKSUM is used for Pelco-P and Pelco-D protocols. If the video turns to slack or
uncontrollable, you can set the
PELCO CHECKSUM
as
ON
to improve the video quality.
System Time Configuration
Steps:
(1)
Move the cursor to
SYS TIME
using the direction buttons and click
IRIS+
to enter.
(2)
Click the left/right direction buttons to position the cursor on the specific item
(year/month/day or hour/minute/second) of which you want to change the value.
(3)
Click the up/down direction buttons to increase/decrease the value.
(4)
Click
IRIS+
button to confirm the settings and exit.
Y - M - D 12 12 12
H - M - S 15 33 25
DONE: OPEN
QUIT: CLOSE
Figure 3-5
Set the System Time
Zero Angle (Initial Position) Configuration
Purpose:
You can define the initial position of the speed dome on the
ZERO ANGLE
submenu.
Steps:
(1)
Move the cursor to
ZERO ANGLE
using the direction buttons and click
IRIS+
to enter.
(2)
Click the left/right/up/down direction buttons to adjust the monitor angle of the speed dome.
(3)
Click
IRIS+
button to confirm the settings and exit.
/R&DOO