User Manual of HD-TVI Speed Dome
© Hikvision
38
position and resume from this position after the linkage action finishes.
The speed dome can be configured to resume the PTZ positions, focus and iris value.
3.5.3
Configuring Alarm Output
Purpose:
An alarm output is a configurable alarm output interface on the speed dome back box which can
connect and trigger another alarm device to operate.
Steps:
1.
Enter the alarm output configuration submenu:
MAIN MENUS > DOME SETTINGS > ALARM OUTPUT
ALARM OUTPUT
ALARM OUTPUT 1 CLOSE
DWELL TIME 2
ALARM OUTPUT 2 OPEN
DWELL TIME 0
BACK EXIT
Figure 3-21
Configure the Alarm Output
2.
Click
IRIS+
to edit the status of the alarm outputs. You can set the alarm output type as
OPEN
(normally open) and
CLOSE
(normally closed).
There is 1 alarm output configurable; configuring the alarm output 2 will be invalid.
3.
Move the cursor to
DWELL TIME
to set the duration of the alarm output signal. The configurable
rage is 0~60 seconds.
4.
Link the alarm output to the configured alarm.
Steps:
(1)
Enter
MAIN MENUS > DOME SETTINGS > ALARM INPUT > ALARM SETTING
and choose the
alarm number that you want to link the alarm output to.
(2)
Move the cursor to
ALARM OUTPUT
and click
IRIS+
to configure the alarm output to the
alarm. You can choose
NONE
to disable alarm outputs, choose
1
to active ALARM OUTPUT
1.
There is 1 alarm output configurable; configuring the alarm output 2 will be invalid.