background image

Thank you for purchasing the Hike Crew™ Inverter Generator 2250. This User Guide is intended to 
provide you with guidelines to ensure that operation of this product is safe and does not pose risk to the 
user. Any use that does not conform to the guidelines described in this User Guide may void the limited 
warranty.

Please read all directions before using the product and retain this guide for reference. This product is 
intended for household use only. It is not intended for commercial use. 

This product is covered by a limited one-year warranty. Coverage is subject to limits and exclusions. 
See warranty for details.

SAFETY PRECAUTIONS

DO NOT, EVER, UNDER ANY CIRCUMSTANCES, RUN THE GENERATOR IN AN INDOOR 
OR ENCLOSED ENVIRONMENT. CARBON MONOXIDE GAS CAN KILL YOU IN MINUTES.

NEVER 

use this generator inside a home or garage, even if doors and windows are open.

 
Only use this generator outside, far away from any windows, doors, or vents leading inside.

Running engines give off carbon monoxide, an odorless, poisonous gas that can cause nausea, 
fainting, and/or death. Do not start or run this engine indoors or in an enclosed area, even if 
windows and doors are open.

Before use, make sure to add gasoline so that the level reaches the red ring in the tank.

Before use, make sure to check the oil level.

The gas from the engine in this generator contains carbon monoxide. Do not under any circumstances 
run this generator indoors or in an improperly ventilated location, as this could cause death.

Always make sure you have provided adequate ventilation while the generator is in operation. 
Failure to do so may result in death.

During and immediately after operation, the muffler will be extremely hot. Do not touch the muffler. 

Gasoline is extremely flammable and explosive. Please take care when storing, filling, and using 
gasoline with this generator.

IT IS OF CRITICAL IMPORTANCE THAT YOU THOROUGHLY READ AND MAKE SURE YOU 
UNDERSTAND ALL SAFETY PRECAUTIONS AND SAFE USE REQUIREMENTS BEFORE 
ATTEMPTING TO USE THIS APPLIANCE. FAILURE TO PROPERLY FOLLOW THE GUIDELINES 
ESTABLISHED HEREIN COULD RESULT IN SEVERE INJURY, FIRE, OR EVEN DEATH.

1

Summary of Contents for HCIG2250

Page 1: ...Inverter Generator 2250 USER GUIDE HCIG2250 ...

Page 2: ...es give off carbon monoxide an odorless poisonous gas that can cause nausea fainting and or death Do not start or run this engine indoors or in an enclosed area even if windows and doors are open Before use make sure to add gasoline so that the level reaches the red ring in the tank Before use make sure to check the oil level The gas from the engine in this generator contains carbon monoxide Do no...

Page 3: ...ontal ground If the generator is placed at an angle it may cause the gasoline to spill or overflow which could lead to equipment damage fires or death Make sure you have mastered the art of quickly shutting off generators and that you understand the operation of all the controls Always keep children and pets away from the operating area of the generator While the engine is running everyone should ...

Page 4: ...r the equivalent should be used Always make sure the generator is properly grounded If the generator is not grounded you risk electrocution Always refer to all applicable local state and federal regulations regarding to grounding Always make sure to conform to electrical safety regulations applicable to the location where you are using the generator Generators should only be loaded up to their rat...

Page 5: ...t socket 5 USB output socket 6 AC output socket 7 Ground protection 8 Parallel socket 9 ECO switch 10 AC overload protector 11 DC overload protector 4 Tank Cap Switch Fuel Tank Cap Body Control Panel Starter Handle Engine Switch Fuel Indicator Spark Plug Maintenance Cover Muffler Exhaust Port Air Filter Oil Maintenance Cover ...

Page 6: ...ing position the engine will continue to run at full speed all the time DC and USB Output Function The DC output voltage at no load is 12 18 V and should only be used with 12 V DC terminals such as batteries The USB output voltage is 5 V and can be used to charge digital products Parallel Function If you want to make use of the power output from two generators for use with high power equipment you...

Page 7: ...5 Once you have used the protection cut off switch five 5 times you will need to restart the engine in order to use the protection cut off switch again PRE OPERATION CHECKLIST Make sure first that the generator is placed on a level horizontal surface and the engine is shut off Do not start the engine until you have completed these checks Check the Oil Level 1 Remove the dipstick and wipe it with a...

Page 8: ...not add more fuel WARNINGS Always use unleaded gasoline of E10 or a higher level to fill the tank Do not use a mixture of oil and gasoline or dirty gasoline Make sure to prevent dirt and water from entering the tank Do not use gasoline containing more than 10 ethanol or gasoline containing methanol as this will seriously damage the engine Always refuel the tank in a well ventilated place while the...

Page 9: ...unctional If necessary clean or replace the filter WARNING Do not run the engine without an air filter or else dirt will enter the engine via the carburetor which causes rapid wear and tear STARTING THE ENGINE WARNINGS Disconnect all electrical equipment from the alternator s AC socket before you start the engine 8 Tank Cap Switch Screw Screw Air Filter Oil Maintenance Cover Screw Air Filter Filte...

Page 10: ...a well ventilated environment Follow these steps to start the engine on your generator 1 Rotate the tank cap switch to the ON position NOTE When you transport the generator always make sure the fuel tank cap switch is cranked into the OFF position 2 Turn the generator engine switch knob to the CHOKE position In this position the choke will be fully closed NOTE If the engine is hotter after startin...

Page 11: ...ge to the shell Always put the starter handle back slowly 4 Turn the engine switch to the running position while the engine is running WARNINGS If the engine fails to start after being shut down check the position of the tank cover switch the engine switch three in one switch and ensure you followed all the steps to starting the engine properly If you did follow steps correctly and all switches ar...

Page 12: ...ength of a cord with a cross sectional area of 2 5 mm2 should not exceed 196 85 60 m for a cross sectional area of 4 0 mm2 this should not exceed 328 08 100 m Keep this generator away from other wires and cables such as distribution networks You can use AC and DC power at the same time When using both the AC and DC sockets make sure that the total power required does not exceed the sum of the AC a...

Page 13: ...tery first and then to the generator Similarly make sure to disconnect the cable from the generator first and then from the battery When charging a car battery with the generator make sure to disconnect the battery ground wire first Once the battery is charged wait until you have removed the charging cable before reconnecting the battery ground wire This will prevent a short circuit or sparks even...

Page 14: ...ights are lit you should first disconnect any electrical equipment If the red error light turns off and the green operating light comes back on you can reconnect the electrical equipment If the green light does not come back on shut down the engine and check it for any malfunctions Low Oil Alarm The low oil level alarm system is designed to prevent engine damage which can occur due to insufficient...

Page 15: ...ring the generator CARE AND MAINTENANCE We have provided a recommended schedule of maintenance in order to keep your generator in the best operating condition and improve engine life and performance WARNINGS Always stop the engine before performing any maintenance If the engine has to be running for some reason make sure you are in a well ventilated area due to the poisonous carbon monoxide contai...

Page 16: ...n or run it for extended periods of time the engine may require servicing more frequently Changing the Oil While the engine is shut down you should make sure to remove the oil quickly and completely 1 Loosen the air filter maintenance cover screws and remove the air filter maintenance cover 15 Regular Service Period Every use Every month or every 10 hrs Every 3 months or every 50 hrs Every 6 month...

Page 17: ...conform to environmental protection requirements pour the used oil into a container seal the container and take it to a service station for recycling Do not throw the used oil into the trash dump it down a drain or pour it on the ground Replacing the Air Filter A dirty air filter will restrict air flow into the carburetor Please clean and maintain your air filter regularly to prevent the carbureto...

Page 18: ... air filter in your generator 1 Loosen the air filter maintenance cover screws and remove the air filter maintenance cover 2 Snap open the air filter cover and remove it 3 Take out the air filter element and clean it with non flammable or high flash point solvent e g kerosene or motorcycle engine oil and then dry it fully 4 Clean the air filter element with clean oil and then squeeze out the exces...

Page 19: ...your spark plugs are in good shape 1 Remove the spark plug maintenance cover 2 Take off the spark plug cap 3 Remove the spark plug using a spark plug spanner 4 Visually inspect the spark plug If the insulator is cracked or chipped replace it with a new one If there is buildup on the plug clean it with a wire brush if you are reusing it 5 Measure the spark plug gap between the center and side elect...

Page 20: ...teps to clean and maintain your spark arrestor 1 Make sure the muffler is cooled completely then loosen the screws on the muffler outlet and remove the spark arrestor 2 Use a brush to clean the carbon deposits on the spark arrestor and inspect it for damage If it is damaged replace it 3 Replace the spark arrestor and re tighten the muffler outlet screws 4 Replace the maintenance cover and tighten ...

Page 21: ...n and tighten the drain screw of the carburetor e Replace the spark plug cap 3 Change the oil 4 Remove the spark plug and pour 2 4 tsp 10 20 ml of engine oil into the cylinder Crank the engine several times to distribute the oil and reinstall the spark plug 5 Pull the starter handle slowly until you feel resistance At this point the piston is coming up on its compression stroke and both the intake...

Page 22: ...S All other products brand names company names and logos are trademarks of their respective owners used merely to identify their respective products and are not meant to connote any sponsorship en dorsement or approval Distributed by C A Marketing Inc 114 Tived Lane East Edison NJ 08837 Made in China 2019 C A IP Holdings LLC All Rights Reserved 21 ...