O P E R A T O R M A N U A L
6
MODEL VLF AC HIPOT SPECIFICATIONS
VLF-50CMF( 50 kV,5.0
µ
F)
Input
230V +/-10%, 50/60 Hz, single phase, 30 A peak, 25 A avg.
Sinusoidal Power Required for full output
Output
Sinusoidal 0-50 kVac peak, 0.1, .05, .02 and .01 Hz frequency
Duty
Continuous
Test Capacitance
5.0
µ
F @ .1 Hz, 10.0
µ
F @ .05 Hz, 25.0
µ
F @ .02 Hz, 50.0
µ
Minimum capacitance to achieve full output- .01
µ
F
Kilovoltmeter
3.5 in. , 0-60 PEAK KILOVOLTS
2% FS Accuracy
Current Meter
3.5 in., 0-200 MILLIAMPERES/6-0uF
5% FS Accuracy
Remote Control Size
Power Section Size
High Voltage Tank size
Complete Trolley
17”w x 11”d x 9.5” high – 20lbs.
20”w x 14”d x 27” high – 160lbs.
13.5”w x 19”d x 23” high – 310lbs.
28”w x 60”d x 51” high
Complete Trolley
775 lbs. (352kg)
Interconnect cable length
Output cable length
20 ft.
Shielded X-Ray/Ground on reels - 100FT.
Table 1 VLF-50CMF Specifications
.