background image

trackspot

®

 Bolt

User Manual

© 

High End

 Systems, Inc. 2011, All Rights Reserved

Information and specifications in this document are subject to change without notice. 

High End

 Systems 

assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual.

Trademarks used in this text: 

High End Systems, Wholehog, trackspot and Lithopatterns are registered trademarks: and Internal Effects, 
the High End Systems globe logo, and the Hog logo are trademarks of 

High End

 Systems, Inc. . Belden is a 

registered trademark of Belden, Inc.

Other trademarks and trade names may be used in this document to refer to either the entities claiming the 
marks and names or their products. High End Systems disclaims any proprietary interest in trademarks and 
trade names owned by others. 

trackspot Bolt User Manual

Version 1.0

Decem

ber, 2011

Summary of Contents for trackspot Bolt

Page 1: ...stems Wholehog trackspot and Lithopatterns are registered trademarks and Internal Effects the High End Systems globe logo and the Hog logo are trademarks of High End Systems Inc Belden is a registered...

Page 2: ...High End Systems 2105 Gracy Farms Lane Austin TX 78758 USA voice 512 836 2242 fax 512 837 5290 Toll Free 800 890 8989 Customer Service High End Systems 2105 Gracy Farms Lane Austin TX 78758 USA voice...

Page 3: ...Amerikanischen und internationalen Sicherheitsvorschriften Ab nderungen dieses Produktes k nnen dessen Sicherheit beeintr chtigen und unter Umst nden gegen die diesbez glichen Sicherheitsnormen verst...

Page 4: ...uld result in personal injury and or damage to equipment This symbol appears adjacent to high voltage warning messages Not heeding these messages could result in serious personal injury 2 m This symbo...

Page 5: ...problem or malfunction Ship returned Product units or parts to 2105 Gracy Farms Lane Austin TX 78758 USA Note Freight Damage Claims are invalid for fixtures shipped in non factory boxes and packing ma...

Page 6: ...6 536 922 US 6 538 797 US 6 545 586 US 6 549 324 US 6 549 326 US 6 563 520 US 6 565 941 US 6 570 348 US 6 575 577 US 6 578 991 US 6 588 944 US 6 592 480 US 6 597 132 US 6 600 270 US 6 601 974 US 6 60...

Page 7: ...el Components 3 Electrical 4 Operation 4 Environmental 4 Cables and Connectors 4 Related Products and Accessories 5 Chapter 2 Installation and Setup Unpacking the trackspot Bolt Fixture 7 Installing t...

Page 8: ...s Enter to store 20 Defog Fan Mode DEFG 21 Mode Menu MODE 22 Selecting Protocol PROT 22 Crossloading the Fixture XLd 22 Test Menu TEST 23 Homing the Fixture HOME 23 Lamp Test LAMP 23 Changing Boot Cod...

Page 9: ...obo Position 32 Rotating Gobo Wheel 33 Rotating Gobo Wheel Function 33 Rotating Gobo Wheel Position 33 Rotating Gobo Rotate Function 34 Rotating Gobo Rotate Coarse Rotating Gobo Rotate Fine 34 Focus 3...

Page 10: ...x trackspot Bolt User Manual...

Page 11: ...olt fixture is a perfect choice for long lasting efficiency Utilizing new technology every motion within the fixture is capable of high speed movement along with smooth slow changes The rotating litho...

Page 12: ...rostepping motor control for smooth motion Computer designed optical components for maximum light efficiency Easy maintenance access Low noise high efficiency cooling system Break resistant mirror 5 p...

Page 13: ...ixture Yoke 17 2 kg 38 lb Dimensions including yoke 371 mm x 370 mm x 760 mm 14 6 in x 14 6 in x 29 9 in Shipping Box Dimensions 457 mm x 404 mm x 879 mm 18 0 in x 15 9 in x 34 6 in Wheel Components L...

Page 14: ...tions for EIA RS 485 applications with the following characteristics Two twisted pairs plus a shield maximum capacitance between conductors 30 pF ft maximum capacitance between conductor and shield 55...

Page 15: ...olehog 3 Lighting Console 25020001 Road Hog Full Boar Lighting Console A6020001 Road Hog Lighting Console A2020001 Heavy duty 5 pin XLR cable 10 55050017 Heavy duty 5 pin XLR cable 25 55050018 Heavy d...

Page 16: ...CHAPTER 1 Product Overview 6 trackspot Bolt User Manual...

Page 17: ...re sending anything to the factory be sure to call your HES dealer distributor for a Return Authorization RA number The factory cannot accept any goods shipped without an RA number Installing the Powe...

Page 18: ...must be connected to the terminal which is marked with the letter L or colored red VIGTIG FIKKER HEDS INFORMATION DANMARK ADVARSEI RESKYTTEKSE MOD ELEKTRISK SHOCK VIGTIGT LEDERE MED GROEN GUL ISOLATIO...

Page 19: ...hat the cable is capable of supporting the weight of the fixture You can order galvanized safety cables from your High End Systems dealer distributor see Related Products and Accessories on page 5 Cla...

Page 20: ...ixture 1 Attach a clamps using any of the three holes on the yoke Use locking washers when attaching the clamp to the yoke 2 Tighten the clamps firmly to the trackspot Bolt yoke and to the support 3 L...

Page 21: ...the data true positive Pins four and five are not used but they allow a secondary data link to pass through the fixture Test each cable with a voltage ohm meter VOM to verify correct polarity and to m...

Page 22: ...ink A terminator on the last fixture of the link prevents data reflection which can corrupt the data communication on the link Powering On the Fixture To power on the trackspot Bolt fixture simply con...

Page 23: ...and Down arrow buttons to select a valid DMX start channel from 0 491 The display will flash a new option ready for selection For more information on addressing your fixture see Address Menu AddR on p...

Page 24: ...ting Down the Fixture A DMX controller can shut down the fixture remotely with the Shutdown option in the Control Channel or you can simply disconnect from power The trackspot Bolt fixture automatical...

Page 25: ...ystem via the four menu navigation buttons on the fixture s front panel The LED display shows the menu items you select from the menu map When accessing fixture options the display will flash when a n...

Page 26: ...pan tilt swap on OFF Set pan tilt swap off DLOS SHRT Turns LED lamp off one second after DMX data is lost LONG Retains LED lamp state after DMX data is lost until the unit is shutdown DEFG MOD1 Defog...

Page 27: ...S UP OFF Setup mode for mechanical homing ON INFO VER Shows the version of software currently loaded on the fixture UNIQ Shows the fixture s unique ID number TEMP CURR Shows the current temperature o...

Page 28: ...universe have overlapping channel ranges one or both devices will be disabled or behave erratically Note The single exception would be if two or more fixtures need to respond to controller commands in...

Page 29: ...an manually turn the fixture s LED display on or off If you want to remotely change the display output using a DMX console see Control Settings on page 36 To turn the display off 1 Press and hold Menu...

Page 30: ...t movement commands in the same direction To swap pan and tilt motion 1 Press and hold Menu until AddR appears on the LED display 2 Scroll to the SET menu Press Enter to select 3 Scroll to the SWAP me...

Page 31: ...lication s requirement To turn the defog fan off 1 Press and hold Menu until AddR appears on the LED display 2 Scroll to the SET menu Press Enter to select 3 Scroll to the dEFG menu Press Enter to sel...

Page 32: ...t fixture can crossload software from one fixture to additional trackspot Bolt fixtures on the same link To crossload software 1 Disconnect the data cable between the console and the first fixture 2 H...

Page 33: ...et you manually turn the LED light engine on or off To access the lamp function 1 Hold MENU until the display changes to AddR 2 Using the up and down buttons scroll to the TEST field and press ENTER t...

Page 34: ...play changes to AddR 2 Using the up and down buttons scroll to the TEST field and press ENTER 3 Using the up and down buttons scroll to the S UP field and press ENTER The display will indicate SET NOW...

Page 35: ...LED display 2 Scroll to the INFO menu Press Enter to select 3 Scroll to the UNIQ option 4 Press Enter The LED will display the fixture s unique ID number Note This option also contains the commands fo...

Page 36: ...tions To reset the minimum and maximum temperature readings 1 Hold MENU until the display changes to AddR 2 Using the up and down buttons scroll to the INFO field and press ENTER 3 Using the up and do...

Page 37: ...with that device for more information To view DMX data for any device on the DMX link 1 Press and hold Menu until AddR appears on the LED display 2 Scroll to the INFO menu Press Enter to select 3 Scr...

Page 38: ...he rotations per second of the lamp power supply fan ERR will display if the fan is not running Viewing the Current Motor and Display Versions VER This menu options shows you the currently loaded moto...

Page 39: ...est length of time after the motor starts moving With MSpeed control change occurs smoothly over the entire MSpeed time value selected For example if you select an MSpeed time of 30 seconds the motor...

Page 40: ...and Tilt motion can be controlled with MSpeed values see MSpeed Motor Speed on page 35 If you choose to use MSpeed for color or gobo changes without affecting Pan and Tilt parameters set Pan Tilt MSpe...

Page 41: ...dexed Takes the quickest path and snaps to the chosen color on the wheel Forward Spin Spins the wheel forward through the colors at variable speeds Reverse Spin Spins the wheel in reverse through the...

Page 42: ...rns plus open on the Static Gobo Wheel Static Gobo Function Description Indexed Takes the quickest path and snaps to the chosen gobo position on the wheel Forward Spin Spins the wheel forward through...

Page 43: ...o Wheel Static Gobo Function Description Indexed Takes the quickest path and snaps to the chosen gobo position on the wheel Forward Spin Spins the wheel forward through the gobo positions at variable...

Page 44: ...otation speed from the slowest at a DMX value 0 to the fastest at a DMX value 255 Focus This parameter gives you control of the focus range When the controller DMX value 0 the focus is fully out Incre...

Page 45: ...e An MSpeed value that is longer than the delay value could produce an undesirable result for example no light output during the scene For a listing of exact MSpeed times see Appendix A MSpeed Convers...

Page 46: ...NOTE The Control channel should not be crossfaded Control Setting Description Safe Disables all Control settings for normal operation Pan Tilt MSpeed Off Sets Pan Tilt MSpeed to ignore MSpeed setting...

Page 47: ...D7 6 89 214 84 D6 7 22 213 84 D5 7 56 212 83 D4 7 91 211 83 D3 8 27 210 82 D2 8 63 209 82 D1 9 00 208 82 D0 9 39 207 81 CF 9 77 206 81 CE 10 17 205 80 CD 10 58 204 80 CC 10 99 203 80 CB 11 41 202 79...

Page 48: ...51 122 91 80 31 50 124 31 79 31 4F 125 73 78 31 4E 127 15 77 30 4D 128 58 76 30 4C 130 02 75 29 4B 134 39 72 28 48 135 86 71 28 47 137 34 70 27 46 138 82 69 27 45 140 32 68 27 44 141 82 67 26 43 143 3...

Page 49: ...espond with the coloured markings identifying the terminals in your plug proceed as follows the core which is coloured green and yellow must be connected to the terminal in the plug which is marked wi...

Page 50: ...orte une protection contre les surcharges de 20A MISE EN GARDE Pour Une Protection Permanente Contre Les Chocs lectriques 1 Assembler le c ble lectrique conform ment aux instructions du manuel 2 D con...

Page 51: ...20A angeschlossen werden WARNUNG Zum Schutz Gegen Gef hrliche K rperstr me 1 Bei der Installation des Netzkabels am Lampensockel folgen Sie bitte Anweisungen in diesem Handbuch 2 Vor Wartungsarbeiten...

Page 52: ...ivado que tenga una protecci n m xima contra las sobrecargas de 20 A ADVERTENCIA Para La Protecci n Continua Contra Electrocuciones 1 Ensamble la tapa del cord n de alimentaci n seg n las instruccione...

Page 53: ...metro 5 Questo apparecchio deve essere collegato alla rete con nterruttore automatico 20A AVVERTENZE Per La Prevenzione Costante Di Scosse Elettriche 1 Assemblare il terminale del cavo seguendo il man...

Page 54: ...Appendix B Important Safety Information 44 trackspot Bolt User Manual...