CHAPTER 3
The Menu System
trackspot
®
Bolt User Manual
19
Set Menu (SET)
Setting Factory Defaults (FACT)
When you set this menu item on, all factory options return to their default settings. trackspot
Bolt fixtures are shipped from the factory with the following default option settings:
The factory default menu option displays
On
if all the factory options are at the factory default
settings. If any of the items listed above are not at the factory default setting, the display reads
OFF. Selecting the
OFF
option will have no effect. To restore the factory default setting:
1. Press and hold <Menu> until
AddR
appears on the LED display.
2. Scroll to the
SET
menu. Press <Enter> to select.
3. Scroll to the
FACT
menu (this will be the first menu displayed). Press <Enter>.
4. Scroll to
ON
to restore the factory option defaults.
5. Press <Enter> to store.
Changing the Display Output (DSPL)
You can manually turn the fixture’s LED display on or off. If you want to remotely change the
display output (using a DMX console), see
Control Settings
on page 36.
To turn the display off:
1. Press and hold <Menu> until
AddR
appears on the LED display.
2. Scroll to the
SET
menu. Press <Enter> to select.
3. Scroll to the
DSPL
menu. Press <Enter> to select.
4. Scroll to
ON
to set the LED display to normal intensity.
5. Press <Enter> to store.
Inverting Pan (P/IN)
This menu item inverts the direction of the pan motor, to allow fixtures mounted opposite each
other horizontally to respond to pan movement commands in the same direction.
To invert the fixture’s pan motion:
1. Press and hold <Menu> until
AddR
appears on the LED display.
2. Scroll to the
SET
menu. Press <Enter> to select.
3. Scroll to the
P/IN
menu. Press <Enter> to select.
4. Scroll to
ON
to invert the fixture’s pan motion, or
OFF
to return the fixture’s pan motion to
normal orientation.
5. Press <Enter> to store.
pan/tilt swap = off
tilt invert = off
pan invert = off
LED display = on and bright
LED off with DMX data loss = short
protocol = STD (standard)