CHAPTER 3
The Menu System
24
Cyberlight
®
2.0 User Manual
Information Menu (INFO)
The Information menu allows you to view current fixture information such as internal
temperature, fixture hours, software version, and DMX data for any other device on the link.
Viewing the Current Software Version (VER)
To view the current software version:
1. Press and hold <Menu> until
AddR
appears on the LED display.
2. Scroll to the
INFO
menu. Press <Enter> to select.
3. Scroll to the
VER
option.
4. Press <Enter>. The LED will display the fixture’s current software version.
Viewing the Unique Fixture ID (UNIQ)
To view the fixture’s identification number:
1. Press and hold <Menu> until
AddR
appears on the LED display.
2. Scroll to the
INFO
menu. Press <Enter> to select.
3. Scroll to the
UNIQ
option.
4. Press <Enter>. The LED will display the fixture’s unique ID number.
Note: This option also contains the commands for setting the ID number for
the first time at the factory. In that case UP and DOWN will be
displayed as the number is generated .
Monitoring Internal Fixture Temperature (TEMP)
The Cyberlight 2.0 menu system lets you monitor the internal fixture temperature at the CPU
board and the lamp power supply. You can view the current, maximum and minimum
temperatures at each of these points or reset the maximum and minimum temperature readings
to the current temperature.
To view the fixture’s current internal temperature:
1. Hold <MENU> until the display changes to
AddR
.
2. Using the up and down buttons, scroll to the
INFO
field and press <ENTER>.
3. Using the up and down buttons, scroll to the
TEMP
field and press <ENTER>.
4. Using the up and down buttons, scroll to the
CURR
field and press <ENTER>.
The fixture will display the current internal temperature followed by C (degrees centigrade)
for the CPU and the LPS locations.